INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Abbreviated terms
5 Principle of mapping to the serial unidirectional
  multidrop point to point link
  5.1 Communication stack
      5.1.1 Physical layer
      5.1.2 Link layer
      5.1.3 Network layer
      5.1.4 Transport layer
      5.1.5 Session layer
      5.1.6 Presentation layer
      5.1.7 Application layer
  5.2 Restrictions
6 Mapping of common types
  6.1 Object name
  6.2 Object reference
7 Mapping of the model for transmission of sampled values
  using multicast
  7.1 Mapping of the multicast sampled values services
  7.2 Mapping of the update of the sampled value buffer
  7.3 Additional definitions for the transmission of sampled
      analogue values
      7.3.1 Application layer functionality
      7.3.2 Presentation layer functionality
      7.3.3 Transport layer functionality
8 Mapping of the common data classes
8.1 Overview
8.2 Additional definitions for the mapping of the common
    data classes
Annex A (normative) Definition of data set instances and
         related multicast sampled value control instances
Annex B (informative) Calculation of required bandwidth
Annex C (informative) Definitions of logical node instance
        names and data names related to the data sets
Annex D (informative) Electronic transformers block diagram
        and configuration example
Annex ZA (normative) Normative references to international
         publications with their corresponding European
         publications
Figures
Tables

Specifies specific communication service mappings for the communication between bay and process level and it specifies a mapping on a serial unidirectional multidrop point to pint link in accordance with IEC 60044-8.

Committee
PEL/57
DevelopmentNote
Supersedes 00/245154 DC (11/2004)
DocumentType
Standard
Pages
34
PublisherName
British Standards Institution
Status
Withdrawn
Supersedes

Lays down the specific communication service mappings for the communication between bay and process level; specifies a mapping on a serial unidirectional multidrop point to point link in accordance with IEC 60044-8. Applies to the communication between merging units of electronic current or voltage-transformers and bay devices such as protection relays.

This publication is of core relevance for Smart Grid.

Standards Relationship
EN 61850-9-1:2003 Identical
DIN EN 61850-9-1:2004-02 Identical
I.S. EN 61850-9-1:2003 Identical
SN EN 61850-9-1 : 2003 Identical
IEC 61850-9-1:2003 Identical
NF EN 61850-9-1 : 2003 Identical

IEC 60044-7:1999 Instrument transformers - Part 7: Electronic voltage transformers
IEC 61850-7-2:2010 Communication networks and systems for power utility automation - Part 7-2: Basic information and communication structure - Abstract communication service interface (ACSI)
IEC 60044-8:2002 Instrument transformers - Part 8: Electronic current transformers
ISO/IEC 8825-1:2015 Information technology ASN.1 encoding rules: Specification of Basic Encoding Rules (BER), Canonical Encoding Rules (CER) and Distinguished Encoding Rules (DER) Part 1:
IEEE 802.3-2012 IEEE Standard for Ethernet
EN 61850-7-2:2010 COMMUNICATION NETWORKS AND SYSTEMS FOR POWER UTILITY AUTOMATION - PART 7-2: BASIC INFORMATION AND COMMUNICATION STRUCTURE - ABSTRACT COMMUNICATION SERVICE INTERFACE (ACSI)
ISO/IEC 8802-3:2000 Information technology Telecommunications and information exchange between systems Local and metropolitan area networks Specific requirements Part 3: Carrier sense multiple access with collision detection (CSMA/CD) access method and physical layer specifications
IEEE 802.1Q-2014 IEEE Standard for Local and metropolitan area networks--Bridges and Bridged Networks
IEC 60874-10-1:1997 Connectors for optical fibres and cables - Part 10-1: Detail specification for fibre optic connector type BFOC/2,5 terminated to multimode fibre type A1
EN 60044-8:2002 Instrument transformers - Part 8: Electronic current transformers
EN 60044-7:2000 Instrument transformers - Part 7: Electronic voltage transformers
IEC 61850-7-3:2010 Communication networks and systems for power utility automation - Part 7-3: Basic communication structure - Common data classes

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.