BS EN 60770-1:1999
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Transmitters for use in industrial-process control systems Methods for performance evaluation
Hardcopy , PDF
02-01-2014
English
06-15-1999
1 Scope and object
2 Normative references
3 Terms and definitions
4 General conditions for tests
5 Analysis and classification of transmitter performance
6 General testing procedures and precautions
7 Test procedures and reporting
8 Other considerations
9 Test report and documentation
Annex A (informative) - Analysis and classification of the
the instrument performance
Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Describes uniform methods of test for the evaluation of the performance of transmitters with pneumatic or electric output signals.
Committee |
GEL/65/2
|
DevelopmentNote |
Supersedes 97/202256 DC and BS 4509(1985) (11/2005) Supersedes 08/30176946 DC. (06/2011)
|
DocumentType |
Standard
|
Pages |
20
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
SupersededBy | |
Supersedes |
Covers individually screened and unscreened pairs or quads in cables having less than 20 pairs/10 quads for horizontal floor wiring. The cables may be provided with a common screen over the cable core. These cables are suitable for the various communication systems for which the reference is given in the appropriate detail specification.
Standards | Relationship |
IEC 60770-1:2010 | Identical |
SN EN 60770-1 : 1999 | Identical |
EN 60770-1:2011 | Identical |
NF EN 60770-1 : 2011 | Identical |
DIN EN 60770-1 : 2011 | Identical |
NBN EN 60770-1 : 2011 | Identical |
I.S. EN 60770-1:2011 | Identical |
IEC 60381-1:1982 | Analogue signals for process control systems. Part 1: Direct current signals |
EN 61298-1:2008 | PROCESS MEASUREMENT AND CONTROL DEVICES - GENERAL METHODS AND PROCEDURES FOR EVALUATING PERFORMANCE - PART 1: GENERAL CONSIDERATIONS |
IEC 61298-1:2008 | Process measurement and control devices - General methods and procedures for evaluating performance - Part 1: General considerations |
EN 61298-3:2008 | Process measurement and control devices - General methods and procedures for evaluating performance - Part 3: Tests for the effects of influence quantities |
IEC 61298-2:2008 | Process measurement and control devices - General methods and procedures for evaluating performance - Part 2: Tests under reference conditions |
EN 60382 : 93 AC 94 | ANALOGUE PNEUMATIC SIGNAL FOR PROCESS CONTROL SYSTEMS |
EN 61298-2:2008 | PROCESS MEASUREMENT AND CONTROL DEVICES - GENERAL METHODS AND PROCEDURES FOR EVALUATING PERFORMANCE - PART 2: TESTS UNDER REFERENCE CONDITIONS |
EN 61000-4-11:2004/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017) |
IEC 61187:1993 | Electrical and electronic measuring equipment - Documentation |
EN 61298-4:2008 | Process measurement and control devices - General methods and procedures for evaluating performance - Part 4: Evaluation report content |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
IEC 61000-4-8:2009 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 60068-2-31:2008 | Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
EN 60770-3:2014 | Transmitters for use in industrial-process control systems - Part 3: Methods for performance evaluation of intelligent transmitters |
HD 452.1 : 200S1 | ANALOGUE SIGNALS FOR PROCESS CONTROL SYSTEMS - DIRECT CURRENT SIGNALS |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60382:1991 | Analogue pneumatic signal for process control systems |
EN 61000-4-8:2010 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
IEC 61298-3:2008 | Process measurement and control devices - General methods and procedures for evaluating performance - Part 3: Tests for the effects of influence quantities |
EN 61000-4-12:2017 | Electromagnetic compatibility (EMC) - Part 4-12: Testing and measurement techniques - Ring wave immunity test |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
EN 61032:1998 | Protection of persons and equipment by enclosures - Probes for verification |
IEC 61298-4:2008 | Process measurement and control devices - General methods and procedures for evaluating performance - Part 4: Evaluation report content |
EN 61000-4-4:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
IEC 60381-2:1978 | Analogue signals for process control systems. Part 2: Direct voltage signals |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 61000-4-6:2014/AC:2015 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013) |
EN 61010-1:2010 | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements |
EN 61000-4-16:2016 | Electromagnetic compatibility (EMC) - Part 4-16: Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz |
IEC 61032:1997 | Protection of persons and equipment by enclosures - Probes for verification |
IEC 61010-1:2010+AMD1:2016 CSV | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements |
IEC 60770-3:2014 | Transmitters for use in industrial-process control systems - Part 3: Methods for performance evaluation of intelligent transmitters |
IEC 60050-300:2001 | International Electrotechnical Vocabulary (IEV) - Part 300: Electrical and electronic measurements and measuring instruments - Part 311: General terms relating to measurements - Part 312: General terms relating to electrical measurements - Part 313: Types of electrical measuring instruments - Part 314: Specific terms according to the type of instrument |
EN 61000-4-10:2017 | Electromagnetic compatibility (EMC) - Part 4-10: Testing and measurement techniques - Damped oscillatory magnetic field immunity test |
EN 60068-2-31:2008 | ENVIRONMENTAL TESTING - PART 2-31: TESTS - TEST EC: ROUGH HANDLING SHOCKS, PRIMARILY FOR EQUIPMENT-TYPE SPECIMENS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.