BS EN 60079-10-2:2015
Current
The latest, up-to-date edition.
Explosive atmospheres Classification of areas. Explosive dust atmospheres
Hardcopy , PDF
English
03-31-2015
Committee |
EXL/31
|
DevelopmentNote |
Supersedes BS EN 61241-10 & 07/30162732 DC. (10/2009)
|
DocumentType |
Standard
|
Pages |
30
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This part of IEC60079 is concerned with the identification and classification of areas where explosive dust atmospheres and combustible dust layers are present, in order to permit the proper assessment of ignition sources in such areas. In this standard, explosive dust atmospheres and combustible dust layers are treated separately. In Clause4, area classification for explosive dusts clouds is described, with dust layers acting as one of the possible sources of release. In Clause7 other general considerations for dust layers are described. The examples in this standard are based on a system of effective housekeeping being implemented in the plant to prevent dust layers from accumulating. Where effective housekeeping is not present, the area classification includes the possible formation of explosive dust clouds from dust layers. The principles of this standard can also be followed when combustible fibres or flyings might cause a hazard. This standard is intended to be applied where there can be a risk due to the presence of explosive dust atmospheres or combustible dust layers under normal atmospheric conditions (see Note1). NOTE1 Atmospheric conditions include variations in pressure and temperature above and below reference levels of 101,3kPa (1013mbar) and 20°C (293K), provided that the variations have a negligible effect on the explosive properties of the combustible materials. It does not apply to underground mining areas, dusts of explosives that do not require atmospheric oxygen for combustion such as pyrophoric substances, propellants, pyrotechnics, munitions, peroxides, oxidizers, water-reactive elements or compounds, or other similar materials. catastrophic failures which are beyond the concept of abnormality dealt with in this standard, any risk arising from an emission of toxic gas from the dust. This standard does not apply to where a hazard might arise due to the presence of flammable gas or vapour, but the principles may be used in the assessment of a hybrid mixture (see also IEC60079‑10‑1 ). NOTE2 Additional guidance on hybrid mixtures is provided in AnnexC. This standard does not take into account the effects of consequential damage following a fire or an explosion.
Standards | Relationship |
IEC 60079-10-2:2015 | Identical |
EN 60079-10-2:2015 | Identical |
11/30218915 DC : DRAFT JAN 2011 | BS 6164 - CODE OF PRACTICE FOR HEALTH AND SAFETY IN TUNNELING IN THE CONSTRUCTION INDUSTRY |
BS 7671(2008) : 2018 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
BS 6164:2011 | Code of practice for health and safety in tunnelling in the construction industry |
12/30258581 DC : 0 | BS 5908-2 - FIRE AND EXPLOSION PRECAUTIONS AT PREMISES HANDLING FLAMMABLE GASES, LIQUIDS AND DUSTS - PART 2: GUIDE TO APPLICABLE STANDARDS AND REGULATIONS |
BS 5908-2:2012 | Fire and explosion precautions at premises handling flammable gases, liquids and dusts Guide to applicable standards and regulations |
BS 7671(2008) : 2008 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
EN 60079-32-2:2015 | Explosive atmospheres - Part 32-2: Electrostatics hazards - Tests |
EN 60079-10-1:2015 | Explosive atmospheres - Part 10-1: Classification of areas - Explosive gas atmospheres |
EN 60079-0:2012/A11:2013 | EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS (IEC 60079-0:2011, MODIFIED) |
IEC 60079-18:2014 RLV | Explosive atmospheres - Part 18: Equipment protection by encapsulation “m” |
ISO 4225:1994 | Air quality General aspects Vocabulary |
IEC 60079-10-1:2015 | Explosive atmospheres - Part 10-1: Classification of areas - Explosive gas atmospheres |
EN 60079-28:2015 | Explosive atmospheres - Part 28: Protection of equipment and transmission systems using optical radiation |
IEC 60050-426:2008 | International Electrotechnical Vocabulary (IEV) - Part 426: Equipment for explosive atmospheres |
EN 60079-31:2014 | Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t" |
EN 60079-11:2012 | Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" |
IEC 60079-11:2011 | Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" |
ISO/IEC 80079-20-2:2016 | Explosive atmospheres Part 20-2: Material characteristics Combustible dusts test methods |
IEC 60079-0:2011 | Explosive atmospheres - Part 0: Equipment - General requirements |
IEC 60079-14:2013 | Explosive atmospheres - Part 14: Electrical installations design, selection and erection |
EN 60079-14:2014/AC:2016 | EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION (IEC 60079-14:2013/COR1:2016) |
IEC 60079-31:2013 | Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t" |
IEC 61241-2-1:1994 | Electrical apparatus for use in the presence of combustible dust - Part 2: Test methods - Section 1: Methods for determining the minimum ignition temperatures of dust |
EN 60079-2:2014/AC:2015 | EXPLOSIVE ATMOSPHERES - PART 2: EQUIPMENT PROTECTION BY PRESSURIZED ENCLOSURE 'P' (IEC 60079-2:2014) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.