BS EN 50525-3-41:2011
Current
The latest, up-to-date edition.
Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables with special fire performance. Single core non-sheathed cables with halogen-free crosslinked insulation, and low emission of smoke
Hardcopy , PDF
English
09-30-2011
1 Scope
2 Normative references
3 Terms and definitions
4 Heat resistant cables (90 degree C)
Annex A (normative) - Tests for cables to EN 50525-3-41
Annex B (normative) - General data
National Annex (informative) - Origins and identification
of the particular cable types
Bibliography
Pertains to non-sheathed single core cables insulated with halogen-free crosslinked compound and having low emission of smoke and corrosive gases when exposed to fire.
Committee |
GEL/20/17
|
DevelopmentNote |
To be read in conjunction with BS EN 50525-1. Supersedes 08/30188842 DC. (10/2011)
|
DocumentType |
Standard
|
Pages |
18
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
EN50525-3-41 applies to non-sheathed single core cables insulated with halogen-free crosslinked compound and having low emission of smoke and corrosive gases when exposed to fire.
NOTE1 Low emission of smoke is checked in accordance with EN61034-2. Low emission of corrosive gases is checked as part of the check for absence of halogens (see AnnexB of EN50525-1).
The cables are of rated voltages U0/U up to and including 450/750V.
NOTE2 Cables rated 450/750V may be used at 600/1000V when this cable is used in fixed installations with mechanical protection, within switchgear and control gear - see HD 516.
The cables are intended for fixed wiring applications.
The maximum conductor operating temperature for each of the cables in this standard is 90°C.
NOTE3 HD 516 contains extensive guidance on the safe use of cables in this standard.
This EN50525-3-41 should be read in conjunction with EN50525-1, which specifies general requirements.
Standards | Relationship |
EN 50525-3-41:2011 | Identical |
BS 7671(2008) : 2018 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
12/30248745 DC : 0 | BS 7211 - ELECTRIC CABLES - THERMOSETTING INSULATED, NON-ARMOURED CABLES FOR VOLTA GES UP TO AND INCLUDING 450/750 V, FOR ELECTRIC POWER, LIGHTING AND INTERNAL WIRING, AND HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE |
BS 7211:2012 | Electric cables. Thermosetting insulated and thermoplastic sheathed cables for voltages up to and including 450/750 V for electric power and lighting and having low emission of smoke and corrosive gases when affected by fire |
BS 7671(2008) : 2008 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
EN 50363-5 : 2005 AMD 1 2011 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 5: HALOGEN-FREE, CROSS-LINKED INSULATING COMPOUNDS |
EN 60719:1993 | Calculation of the lower and upper limits for the average outer dimensions of cables with circular copper conductors and of rated voltages up to and including 450/750 V |
IEC 60228:2004 | Conductors of insulated cables |
EN 60228:2005 COR 2005 | CONDUCTORS OF INSULATED CABLES |
EN 60332-1-2:2004/A11:2016 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004/A1:2015) |
IEC 60332-1-2:2004+AMD1:2015 CSV | Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame |
IEC 60719:1992 | Calculation of the lower and upper limits for the average outer dimensions of cables with circular copper conductors and of rated voltages up to and including 450/750 V |
EN 50525-1:2011 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 1: General requirements |
EN 61034-2:2005/A1:2013 | MEASUREMENT OF SMOKE DENSITY OF CABLES BURNING UNDER DEFINED CONDITIONS - PART 2: TEST PROCEDURE AND REQUIREMENTS (IEC 61034-2:2005/A1:2013) |
HD 516 S2:1997/A2:2008 | GUIDE TO USE OF LOW VOLTAGE HARMONIZED CABLES |
EN 50395 : 2005 AMD 1 2011 | ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES |
IEC 60811-1-4:1985 | Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Four: Tests at low temperature |
IEC 61034-2:2005+AMD1:2013 CSV | Measurement of smoke density of cables burning under definedconditions - Part 2: Test procedure and requirements |
EN 50396 : 2005 AMD 1 2011 | NON ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES |
EN 60811-1-4:1995/A2:2001 | INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1-4: GENERAL APPLICATION - TESTS AT LOW TEMPERATURE |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.