BS EN 50130-5:2011
Current
The latest, up-to-date edition.
Alarm systems Environmental test methods
Hardcopy , PDF
English
08-31-2011
1 Scope
2 Normative references
3 Terms and definitions
4 Environmental classes
5 Standard laboratory conditions
6 Tolerances
7 Information to be included in the relevant product standard
8 Dry heat (operational)
9 Dry heat (endurance)
10 Cold (operational)
11 Temperature change (operational)
12 Damp heat, steady state (operational)
13 Damp heat, steady state (endurance)
14 Damp heat, cyclic (operational)
15 Damp heat, cyclic (endurance)
16 Water ingress (operational)
17 Sulphur dioxide (SO[2]) (endurance)
18 Salt mist, cyclic (endurance)
19 Shock (operational)
20 Impact (operational)
21 Free fall (operational)
22 Vibration, sinusoidal (operational)
23 Vibration, sinusoidal (endurance)
24 Simulated solar radiation, temperature rise (operational)
25 Simulated solar radiation, surface degradation (endurance)
26 Dust tightness (endurance)
Bibliography
Describes environmental test methods to be used for testing the system components of the following alarm systems, intended for use in and around buildings: - intruder alarm systems; - hold-up alarm systems; - social alarm systems; - CCTV systems, for security applications; - access control systems, for security applications; - alarm transmission systems.
Committee |
GW/1/1
|
DevelopmentNote |
Supersedes 95/521591 DC (08/2004) Supersedes 10/30218875 DC. (08/2011)
|
DocumentType |
Standard
|
Pages |
42
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This European Standard specifies environmental test methods to be used for testing the system components of the following alarm systems, intended for use in and around buildings: intruder alarm systems; hold-up alarm systems; social alarm systems; CCTV systems, for security applications; access control systems, for security applications; alarm transmission systems 1). This European Standard specifies three equipment classes (fixed, movable & portable equipment) and four environmental classes. The environmental classes only include the general service environments envisaged for equipment installed in typical residential, commercial and industrial environments. It may be necessary for the product standard to require additional or different environmental tests or severities where there could be specific environmental problems (e.g. some different severities may be required for break glass detectors stuck to glass windows, due to the local extremes of temperature and humidity), the test exposure falls within the intended detection phenomenon of the detector (e.g. during a vibration test on a seismic detector). In order to provide reproducible test methods and to avoid the proliferation of technically similar test methods, the test procedures have been chosen, where possible, from internationally accepted standards (e.g. IEC publications). For specific guidance on these tests, reference should be made to the appropriate document, which is indicated in the relevant sub-section. For more general guidance and background information on environmental testing, reference should be made to EN 60068-1 and to the EN 60068-3 series. This European Standard does not specify the requirements or performance criteria to be applied, which should be specified in the relevant product standard, special tests only applicable to a particular device (e.g. the effects of turbulent air draughts on ultrasonic movement detectors), basic safety requirements, such as protection against electrical shocks, unsafe operation, insulation coordination and related dielectric tests, tests relating to deliberate acts of damage or tampering.
Standards | Relationship |
I.S. EN 50130-5:2011 | Identical |
NBN EN 50130-5 : 2011 | Identical |
NEN EN 50130-5 : 2011 | Identical |
NF EN 50130-5 : 2011 | Identical |
UNE-EN 50130-5:2011 | Identical |
EN 50130-5:2011 | Identical |
SN EN 50130-5 : 1999 | Identical |
DIN EN 50130-5 : 2012 | Identical |
BS 8418(2015) : 2015 | INSTALLATION AND REMOTE MONITORING OF DETECTOR-ACTIVATED CCTV SYSTEMS - CODE OF PRACTICE |
14/30293253 DC : 0 | BS 8418 - INSTALLATION AND REMOTE MONITORING OF DETECTOR-ACTIVATED CCTV SYSTEMS - CODE OF PRACTICE |
09/30181219 DC : 0 | BS 8418 - INSTALLATION AND REMOTE MONITORING OF DETECTOR-ACTIVATED CCTV SYSTEMS - CODE OF PRACTICE |
BS 8584:2015 | Vacant property protection services. Code of practice |
BS 8418:2003 | Installation and remote monitoring of detector activated CCTV systems. Code of practice |
BS 8418:2010 | Installation and remote monitoring of detector-activated CCTV systems. Code of practice |
EN 62262:2002 | Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) |
IEC 60068-2-5:2010 | Environmental testing - Part 2-5: Tests - Test Sa: Simulated solar radiation at ground level and guidance for solar radiation testing |
EN 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60068-2-18:2017 | Environmental testing - Part 2-18: Tests - Test R and guidance: Water |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
EN 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
EN 60068-2-18:2017 | Environmental testing - Part 2-18: Tests - Test R and guidance: Water |
IEC 60068-2-31:2008 | Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens |
EN 60068-2-27:2009 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 62262:2002 | Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) |
IEC 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
EN 60068-2-78:2013 | Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state |
EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 60068-2-5:2011 | Environmental testing - Part 2-5: Tests - Test Sa: Simulated solar radiation at ground level and guidance for solar radiation testing |
EN 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
IEC 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
EN 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
IEC 60068-2-52:2017 | Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution) |
EN 60068-2-31:2008 | ENVIRONMENTAL TESTING - PART 2-31: TESTS - TEST EC: ROUGH HANDLING SHOCKS, PRIMARILY FOR EQUIPMENT-TYPE SPECIMENS |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |