• Shopping Cart
    There are no items in your cart

BS 8206-2:1992

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Lighting for buildings Code of practice for daylighting

Available format(s)

Hardcopy , PDF

Superseded date

09-30-2008

Superseded by

BS 8206-2:2008

Language(s)

English

Published date

06-15-1992

US$302.14
Excluding Tax where applicable

Committees responsible
Foreword
Code of Practice
Section 1. General
1. Scope
2. Definitions
2.1 General
2.2 Sunlight
2.3 Skylight
Section 2. Aims and criteria for design
3. The contribution of daylight
4. Windows and view
4.1 Principle
4.2 Analysis of view
4.3 View in urban areas
4.4 Size and proportion of windows
5. Daylight and room brightness
5.1 General
5.2 Sunlight: principle
5.3 Sunlight duration
5.4 Skylight: principle
5.5 Average daylight factor
5.6 Minimum values of average daylight factor in
     dwellings
5.7 Uniformity
5.8 Contrast between the interior and the view outside
6. Daylight for task lighting
6.1 General
6.2 Quantity of daylight
6.3 Quality of daylight
Section 3. Further design issues
7. Electric lighting used in conjunction with daylight
7.1 Functions of supplementary electric lighting design
7.2 Enhancement of room brightness
7.3 Task lighting
7.4 Change in lighting at dusk
8. Sunlight shading
8.1 General
8.2 Overshadowing
9. Energy efficiency
9.1 Energy consumption in lighting
9.2 Window design and energy efficiency
9.3 Passive solar design
9.4 Lighting controls
10. Conservation of materials inside buildings
10.1 General
10.2 Factors affecting degradation
10.3 Improving conservation
11. Statutory requirements affecting the provision of
     daylight
11.1 General
11.2 Rights of light
11.3 Building regulations
Section 4. Methods of calculation
12. Sunlight
12.1 Sunpath diagrams
12.2 Probable sunlight hours
12.3 Use of models
13. Calculation of average daylight factor
13.1 Windows and rooflights with continuous obstructions
     of uniform height
13.2 Limitations of the formula
13.3 Room depth
14. Calculation of daylight illuminance
14.1 General
14.2 Calculation of daylight factors at a given point
15. Examples of the calculation of window transmittance
15.1 Average daylight factor
15.2 Daylight factor at a point
15.3 Overall aperture and net glazed area
Appendices
A. Data for daylight and sunlight calculations
A.1 Daylight factor tables
A.2 Values of reflectance and transmittance
A.3 Availability of sunlight
A.4 Availability of skylight
B. Standard service and design service illuminances
C. Bibliography
Tables
1. Minimum glazed areas for view when windows are
     restricted to one wall
2. Sky component (CIE overcast sky) for vertical glazed
     rectangular windows
3. Conversion of average to minimum internally
     reflected component
4. Approximate values of the reflectance of light
5. Correction factors for deterioration of interior
     surfaces, to be applied to the internally reflected
     component
6. Mean light transmittance and correction factors of
     glazing materials
7. Correction factors for dirt on glass
8. Correction factors for frames and glazing bars
9. Diffuse orientation factors for an 09.00 to 17.00
     working day
10. Examples of activities/interiors appropriate for
     each standard service illuminance
Figures
1. Window reveal drawn on a sunpath diagram for London
2. Obstructing building superimposed on the sunpath
     diagram
3. Use of sunlight probability diagram to determine
     sunlight reaching window reference point
4. Angle of visible sky used in calculating average
     daylight factor
5. Limiting depth of a side-lit room
6. Dimensions used in BRS simplified daylight table
7. Use of daylight protractors
8. Typical spectral transmission curve of 6 mm clear
     float glass
9. Sunpath diagram for London (latitude 51 deg N)
10. Sunpath diagram for Edinburgh (latitude 56 deg N)
11. Sunlight probability diagram
12. Diffuse illuminance (Eh) availability for London
13. Diffuse illuminance (Eh) availability for Edinburgh
14. Mean horizontal diffuse illuminances at London (Kew)
15. Spectral composition of north sky daylight at 5700
     deg K
16. Flow chart for obtaining design service illuminance
     from standard service illuminance
Index

Includes the design of electric lighting when used in conjunction with daylight. Sunlight and skylight data are given.

Committee
EL/1
DevelopmentNote
Supersedes 90/16169 DC, BS DD67(1980) and BS DD73(1982) (10/2005)
DocumentType
Standard
Pages
44
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

BS 6229:2003 Flat roofs with continuously supported coverings. Code of practice
DEFSTAN 00-250(PT3)SEC1-7/1(2008) : 2008 HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 3: TECHNICAL GUIDANCE - SECTIONS 1-7 - OVERALL CONTENTS/SCOPE
DEFSTAN 00-250(PT1)/1(2008) : 2008 HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 1: OVERARCHING PEOPLE-RELATED REQUIREMENTS
DEFSTAN 00-250(PT3)SEC11/1(2008) : 2008 HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 3: TECHNICAL GUIDANCE - SECTION 11 - TRAINING
DEFSTAN 00-250(PT3)SEC8/1(2008) : 2008 HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 3: TECHNICAL GUIDANCE - SECTION 8 - PEOPLE IN SYSTEMS
DEFSTAN 00-250(PT3)SEC9/1(2008) : 2008 HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 3: TECHNICAL GUIDANCE - SECTION 9 - PEOPLE CHARACTERISTICS
DEFSTAN 00-250(PT3)SEC10/1(2008) : 2008 HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 3: TECHNICAL GUIDANCE - SECTION 10 - SYSTEMS SAFETY
DEFSTAN 00-250(PT3)SEC15/1(2008) : 2008 HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 3: TECHNICAL GUIDANCE - SECTION 15 - WORK EQUIPMENT
DEFSTAN 00-250(PT3)SEC13/1(2008) : 2008 HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 3: TECHNICAL GUIDANCE - SECTION 13 - THE WORKPLACE
DEFSTAN 00-250(PT3)SEC12/1(2008) : 2008 HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 3: TECHNICAL GUIDANCE - SECTION 12 - OPERATIONS, MAINTENANCE & SUPPORT
DEFSTAN 00-250(PT3)SEC16/1(2008) : 2008 HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 3: TECHNICAL GUIDANCE - SECTION 16 - LIVING SPACES
DEFSTAN 00-250(PT2)/1(2008) : 2008 HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 2: PARTICULAR PEOPLE-RELATED REQUIREMENTS
DEFSTAN 00-250(PT3)SEC14/1(2008) : 2008 HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 3: TECHNICAL GUIDANCE - SECTION 14 - THE ENVIRONMENT
BS 6262-1:2005 Glazing for buildings General methodology for the selection of glazing
BS 5516-2:2004 Patent glazing and sloping glazing for buildings Code of practice for sloping glazing
BS 8409:2002 Soft indoor play areas. Code of practice
BS 5837:2005 Trees in relation to construction. Recommendations
BS 6262-2:2005 Glazing for buildings Code of practice for energy, light and sound
BS 7083:1996 Guide to the accommodation and operating environment for information technology (IT) equipment
EI MODEL CODE SAFE PRACTICE PT7 : 1998 DESIGN, CONSTRUCTION, OPERATION AND MAINTENANCE OF AVIATION FUELLING FACILITIES
04/19990343 DC : DRAFT NOV 2004 BS 6262-1 - CODE OF PRACTICE FOR GLAZING FOR BUILDINGS - PART 1: GENERAL

BS 8220-3:1990 Guide for security of buildings against crime Warehouses and distribution units
BS 8206-1:1985 Lighting for buildings Code of practice for artificial lighting
BS 8211-1:1988 Energy efficiency in housing Code of practice for energy efficient refurbishment of housing
BS 8207:1985 Code of practice for energy efficiency in buildings
BS 8220-2:1987 Guide for security of buildings against crime Offices and shops
BS 8220-1:1986 Guide for security of buildings against crime Dwellings

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.