BS 5885-2:1987
Current
The latest, up-to-date edition.
Automatic gas burners Specification for packaged burners with input rating 7.5 kW up to but excluding 60 kW
Hardcopy , PDF
English
06-30-1987
Foreword
Committees responsible
Specification
1. Scope
2. Definitions
3. Verification
4. Gas flow pipework and controls
4.1 Strainers
4.2 Pipework and flow components
4.3 Gas supply
4.4 Safety shut-off systems
5. Combustion air, pre-purge and post-purge
5.1 Combustion air
5.2 Pre-purge and post-purge
6. Electrical supply and ancillary equipment
6.1 Electricity supply
6.2 Electrical equipment
7. Flame safeguards
7.1 Flame detection
7.2 Start-gas flame establishment
7.3 Main flame establishment
8. Control system requirements
9. Fuel/air ratio control
10. Manufacturer's literature
11. Marking
12. Commissioning instructions
Tables
1. Test gases
2. Wall thickness of pipes complying with BS 3601
3. Flame safeguard drop-out times
Requirements (primarily safety requirements) for small packaged burners employing forced and induced draught. May be designed for 1st, 2nd and 3rd family gases. Covers single burners and dual fuel burners when operating only on gas.
Committee |
RHE/13
|
DevelopmentNote |
Supersedes 85/72398 DC (10/2003) Reviewed and confirmed by BSI, February 2010. (01/2010)
|
DocumentType |
Standard
|
Pages |
18
|
PublisherName |
British Standards Institution
|
Status |
Current
|
SupersededBy |
This Part of BS 5885 specifies minimum requirements for automatic forced and induced draught packaged gas burners with heat input ratings of 7.5 kW up to but excluding 60 kW and capable of operating with 1st, 2nd or 3rd family gases at pressures not exceeding 35 mbar1) at the inlet to the control train supplied with the burner.
BS 5885 applies to burners intended for use in industrial processes. It does not cover burners intended for use in heating appliances, e.g. boilers, which are covered by BS EN 676, Automatic forced draught burners for gaseous fuels.
It covers single burners, and dual fuel burners when operating only on gas. It does not cover multi-burners.
It relates primarily to the safety aspects of automatic control and operation. It does not provide a complete specification for automatic burners and their ancillary equipment.
NOTE 1 The use of gases which are dirty, wet, of variable composition or high dewpoint may cause difficulties which are not covered in detail by this Part of BS 5885. In such cases, suppliers and users of equipment will need to take additional measures to comply with the requirements of this standard.
NOTE 2 The titles of the publications referred to in this standard are listed on pages 12 and 13.
1) 1 mbar = 100 N/m2 = 100 Pa.
03/310868 DC : DRAFT JUNE 2003 | BS 6644 - SPECIFICATION FOR INSTALLATION OF GAS-FIRED HOT WATER BOILERS OF RATED INPUTS BETWEEN 70KW (NET) AND 2MW (GROSS) (2ND AND 3RD FAMILY GASES) |
BS 6644:1991 | Specification for installation of gas-fired hot water boilers of rated inputs between 60 kW and 2 MW (2nd and 3rd family gases) |
BS 6644(2005) : 2005 | SPECIFICATION FOR INSTALLATION OF GAS-FIRED HOT WATER BOILERS OF RATED INPUTS BETWEEN 70 KW (NET) AND 1.8 MW (NET) (2ND AND 3RD FAMILY GASES) |
BS 6644:1990 | Specification for installation of gas-fired hot water boilers of rated inputs between 60 kW and 2 MW (2nd and 3rd family gases) |
BS 6644:2011 | Specification for the installation and maintenance of gas-fired hot water boilers of rated inputs between 70 kW (net) and 1.8 MW (net) (2nd and 3rd family gases) |
BS 6230:1991 | Specification for installation of gas-fired forced convection air heaters for commercial and industrial space heating (2nd family gases) |
11/30229801 DC : 0 | BS 6644 - SPECIFICATION FOR THE INSTALLATION OF GAS-FIRED HOT WATER BOILERS OF RATED INPUTS BETWEEN 70 KW (NET) AND 1.8 MW (NET) (2ND AND 3RD FAMILY GASES) |
EI MODEL CODE SAFE PRACTICE PT1 : 2010 | THE SELECTION, INSTALLATION, INSPECTION, AND MAINTENANCE OF ELECTRICAL AND NON ELECTRICAL APPARATUS IN HAZARDOUS AREAS |
BS 5986:1980 | Specification for electrical safety and performance of gas fired space heating appliances with inputs 60 kW to 2 MW |
BS 5963:1981 | Specification for electrically operated automatic gas shut-off valves |
BS 2051-1:1973 | Tube and pipe fittings for engineering purposes Copper and copper alloys capillary and compression tube fittings for engineering purposes |
BS 3016:1989 | Specification for pressure regulators for liquefied petroleum gases |
BS 2640:1982 | Specification for Class II oxy-acetylene welding of carbon steel pipework for carrying fluids |
BS 3955:1986 | Specification for electrical controls for household and similar general purposes |
BS 1179-6:1980 | Glossary of terms used in the gas industry Combustion and utilization including installation at consumers\' premises |
BS 2871-1:1971 | Specification for copper and copper alloys. Tubes Copper tubes for water, gas and sanitation |
BS 1560-2:1970 | Circular flanges for pipes, valves and fittings (Class designated) Specification for steel pipe flanges (nominal sizes ½ in to 24 in). Metric dimensions |
BS 1387:1985 | Specification for screwed and socketed steel tubes and tubulars and for plain end steel tubes suitable for welding or for screwing to BS 21 pipe threads |
BS 2051-2:1984 | Tube and pipe fittings for engineering purposes Specification for olive type copper alloy compression tube fittings |
BS 1740-1:1971 | Specification for wrought steel pipe fittings (screwed BS 21 R-series thread) Metric units |
BS 1723-1:1986 | Brazing Specification for brazing |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.