1 - ATS 5200.501-2011 TECHNICAL SPECIFICATION FOR PLUMBING AND DRAINAGE PRODUCTS - ANTI-INFILTRATION OVERFLOW-RELIEF DEVICE
4 - PREFACE
5 - CONTENTS
6 - 1 SCOPE
6 - 2 APPLICATION
6 - 3 REFERENCED DOCUMENTS
7 - 4 DEFINITIONS
7 - 4.1 Overflow relief
7 - 5 MATERIALS
7 - 5.1 General
7 - 5.2 Elastomeric materials
7 - 5.3 Other materials
7 - 6 MARKING
7 - 7 PACKAGING
7 - 8 DESIGN
7 - 8.1 General
8 - 8.2 Dimensions
8 - 8.3 Connections
8 - 8.4 Freedom from defects
8 - 9 PERFORMANCE REQUIREMENTS AND TEST METHODS
8 - 9.1 Infiltration test
8 - 9.2 Overflow-relief test
8 - 9.3 Load test
8 - 9.4 High temperature stress-relief test
9 - 9.5 Performance test for foot ventilation of overflow relief and disconnector gullies
9 - 10 TEST SEQUENCE AND TEST SAMPLE PLAN
9 - 11 PRODUCT DOCUMENTATION
10 - APPENDIX A - MEANS FOR DEMONSTRATING COMPLIANCE WITH THIS AUSTRALIAN TECHNICAL SPECIFICATION
10 - A1 SCOPE
10 - A2 RELEVANCE
10 - A3 PRODUCT CERTIFICATION
10 - A4 DEFINITIONS
10 - A4.1 Batch release test
10 - A4.2 Production batch
10 - A4.3 Sample
10 - A4.4 Sampling plan
10 - A4.5 Type test batch
11 - A4.6 Type testing (TT)
11 - A5 TESTING
11 - A5.1 Type testing
11 - A5.2 Batch release testing
11 - A5.3 Retesting
13 - APPENDIX B - INFILTRATION TEST
13 - B1 SCOPE
13 - B2 PRINCIPLE
13 - B3 APPARATUS
13 - B4 PROCEDURE
13 - B5 TEST REPORT
15 - APPENDIX C - OVERFLOW-RELIEF TEST
15 - C1 SCOPE
15 - C2 PRINCIPLE
15 - C3 APPARATUS
15 - C4 PROCEDURE
15 - C5 TEST REPORT
17 - APPENDIX D - FOOT VENTILATION TEST
17 - D1 SCOPE
17 - D2 PRINCIPLE
17 - D3 APPARATUS
17 - D4 PROCEDURE
17 - D4.1 General
18 - D4.2 Test A-Open grate
18 - D4.3 Test B-Riser pipe
18 - D4.4 Test C-Overflow relief device
18 - D5 TEST REPORT

This Australian Technical Specification sets out requirements for moulded PVC-U anti-infiltration overflow-relief devices, of nominal size DN 100, that are intended, upon installation in an overflow relief gully (ORG), to prevent the infiltration of surface waters to the sewerage and drainage systems and provide for the overflow relief of any surcharge of the sewerage and drainage systems.

Committee
WS-031
DocumentType
Technical Specification
ISBN
978 0 7337 9881 8
Pages
16
PublisherName
Standards Australia
Status
Withdrawn
Supersedes

This Australian Technical Specification sets out requirements for moulded PVC-U anti-infiltration overflow-relief devices, of nominal size DN 100, that are intended, upon installation in an overflow relief gully (ORG), to prevent the infiltration of surface waters to the sewerage and drainage systems and provide for the overflow relief of any surcharge of the sewerage and drainage systems.Anti-infiltration overflow-relief devices require certification to WaterMark Level 2.

First published as ATS 5200.501-2009.
Second Edition 2011.

AS/NZS 3500.5:2000 Plumbing and Drainage Domestic installations
AS/NZS 1260:2009 PVC-U pipes and fittings for drain, waste and vent application
AS 5200.000-2006 Technical specification for plumbing and drainage products Procedures for certification of plumbing and drainage products (Reconfirmed 2018)
AS/NZS 1462.1:2006 Methods of test for plastics pipes and fittings Method for determining the dimensions of pipes and fittings (Reconfirmed 2024)
AS 1646-2007 Elastomeric seals for waterworks purposes (Reconfirmed 2018)
AS/NZS 3500.0:2003 Plumbing and drainage Glossary of terms
AS/NZS 1462.11:1996 Methods of test for PVC pipes and fittings Method for high temperature stress-relief testing of fittings (Reconfirmed 2017)
AS 2888.6-2002 Methods of testing plastics waste fittings Method for load testing of plastics waste outlets
AS/NZS 3500.2:2003 Plumbing and drainage Sanitary plumbing and drainage

Access your standards online with a subscription