ASTM E 1622 : 1994 : R1999 : EDT 1
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Standard Practice for Correction of Spectral Line Overlap in Wavelength-Dispersive X-Ray Spectrometry (Withdrawn 2006)
Hardcopy , PDF
06-08-2006
English
11-10-1999
CONTAINED IN VOL. 03.05, 2005 Defines procedures for the correction of line overlap interferences encountered in the analysis of metallic and non-metallic specimens in wavelength dispersive X-ray spectrometry.
Committee |
E 01
|
DocumentType |
Standard Practice
|
Pages |
5
|
PublisherName |
American Society for Testing and Materials
|
Status |
Withdrawn
|
1.1 Procedures are given for the correction of line overlap interferences encountered in the analysis of metallic and nonmetallic specimens in wavelength dispersive X-ray spectrometry.
1.2 Spectral interference occurs when a line of another element appears at or close to the same wavelength as the analyte line. The interfering line or lines may be from the same spectral order as the analyte line or may be from another spectral order. Line overlap interferences from higher order lines are usually removed when pulse-height discrimination is used.
1.3 The procedures given in this practice are applicable to making corrections for interferences arising from concomitants in the sample. Interfering lines from the X-ray tube and associated instrumental components are usually specific to the system and the procedure for dealing with these may be found elsewhere. This is treated by E. P. Bertin.
1.4 This practice is not generally applicable to simultaneous X-ray spectrometers if it is not possible to measure a line of the interfering element. Correction is possible, however, if the concentration of the interfering element is known and can be entered into the analytical program.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
I.S. EN 62321-3-1:2014 | DETERMINATION OF CERTAIN SUBSTANCES IN ELECTROTECHNICAL PRODUCTS - PART 3-1: SCREENING - LEAD, MERCURY, CADMIUM, TOTAL CHROMIUM AND TOTAL BROMINE BY X-RAY FLUORESCENCE SPECTROMETRY |
ASTM D 7085 : 2004 : EDT 1 | Standard Guide for Determination of Chemical Elements in Fluid Catalytic Cracking Catalysts by X-ray Fluorescence Spectrometry (XRF) |
EN 62321-3-1:2014 | Determination of certain substances in electrotechnical products - Part 3-1: Screening - Lead, mercury, cadmium, total chromium and total bromine by X-ray fluorescence spectrometry |
ASTM E 2465 : 2013 : REDLINE | Standard Test Method for Analysis of Ni-Base Alloys by Wavelength Dispersive X-Ray Fluorescence Spectrometry |
BS EN 62321-3-1:2014 | Determination of certain substances in electrotechnical products Screening. Lead, mercury, cadmium, total chromium and total bromine by X-ray fluorescence spectrometry |
IWA 8:2009 | Tableware, giftware, jewellery, luminaries Glass clarity Classification and test method |
ASTM D 7085 : 2004 : R2018 | Standard Guide for Determination of Chemical Elements in Fluid Catalytic Cracking Catalysts by X-ray Fluorescence Spectrometry (XRF) |
ASTM E 2465 : 2013 | Standard Test Method for Analysis of Ni-Base Alloys by Wavelength Dispersive X-Ray Fluorescence Spectrometry |
ASTM D 7085 : 2004 | Standard Guide for Determination of Chemical Elements in Fluid Catalytic Cracking Catalysts by X-ray Fluorescence Spectrometry (XRF) |
ASTM D 7085 : 2004 : R2010 : EDT 1 | Standard Guide for Determination of Chemical Elements in Fluid Catalytic Cracking Catalysts by X-ray Fluorescence Spectrometry (XRF) |
IEC 62321:2008 | Electrotechnical products - Determination of levels of six regulated substances (lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, polybrominated diphenyl ethers) |
10/30229251 DC : 0 | BS EN 62321-3-1 ED 1 - DETERMINATION OF CERTAIN SUBSTANCES IN ELECTRO TECHNICAL PRODUCTS - PART 3-1: SCREENING ELECTRO TECHNICAL PRODUCTS FOR LEAD, MERCURY, CADMIUM, TOTAL CHROMIUM AND TOTAL BROMINE USING X-RAY FLUORESCENCE SPECTROMETRY |
BS EN 62321:2009 | Electrotechnical products. Determination of levels of six regulated substances (lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, polybrominated diphenyl ethers) |
I.S. EN 62321:2009 | ELECTROTECHNICAL PRODUCTS - DETERMINATION OF LEVELS OF SIX REGULATED SUBSTANCES (LEAD, MERCURY, CADMIUM, HEXAVALENT CHROMIUM, POLYBROMINATED BIPHENYLS, POLYBROMINATED DIPHENYL ETHERS) |
EN 62321:2009 | Electrotechnical products - Determination of levels of six regulated substances (lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, polybrominated diphenyl ethers) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.