AS 2488-1995
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Resuscitators intended for use with humans
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
06-30-2017
01-05-1996
Specifies performance and safety requirements for ventilatory resuscitators intended for use with humans of all age groups. Automatic pressure cycled gas-powered resuscitators, electrically-powered resuscitators, devices which are designed only to deliver gases to a patient breathing adequately, and devices intended to assist or provide ventilation to a patient for an extended period of time are not covered. The Clauses of this Standard supplement or modify the corresponding Clauses in ISO 8382:1988.
Committee |
HE-018
|
DocumentType |
Standard
|
ISBN |
0 7262 9396 2
|
Pages |
33
|
PublisherName |
Standards Australia
|
Status |
Withdrawn
|
Supersedes |
This Standard specifies minimum performance and safety requirements for ventilatory resuscitators intended for use with humans of all age groups. It specifies the performance of operator-powered and gas-powered ventilatory resuscitators which are portable and intended for use in emergency situations to provide lung ventilation to humans whose breathing is inadequate. Requirements for partial rebreathing and circle systems are also included. For gas-powered resuscitators, gas supply requirements are included. Requirements are included for suction systems which may be supplied with the resuscitator. Resuscitators for infants and children are designated according to body mass range and approximate age equivalent. Automatic pressure-cycled gas-powered resuscitators are not dealt with in the Standard because serious under-ventilation is likely if the patient has a high airway resistance or a low compliance of the lungs or chest wall (or both). Such resuscitators are also not suitable for use during external cardiac compression. Electrically powered resuscitators, devices which are designed only to deliver gases to a patient breathing adequately and devices which are intended to assist or provide for the ventilation of a patient for an extended period of time are also not covered by this Standard. Appendix A details test methods, while Appendix B provides tables of resistances and compliances required to set up the test lung.NOTE: Appendix C gives a rationale for various Clauses in this Australian Standard and is included to provide additional insight into the reasoning that led to the requirements and recommendations that have been given. Appendices D and E provide advice concerning materials to be used in resuscitators and face masks.
Standards | Relationship |
ISO 8382:1988 | Corresponds |
First published as AS 2488-1981.
Second edition 1995.
AS 2896-1998 | Medical gas systems - Installation and testing of non-flammable medical gas pipeline systems |
AS 2120.2-1992 | Medical suction equipment Manually-powered suction equipment |
AS 2120.1-1992 | Medical suction equipment Electrically-powered suction equipment Safety requirements |
AS/NZS 2496:1995 | Breathing attachments for anaesthetic purposes for human use |
AS 2472-1996 | Valves for medical gas cylinders (Including pin-indexed outlet) |
AS 2900.3-2002 | Quantities and units - Mechanics |
AS 2900.3-1986 | Quantities, units, and symbols - Quantities and units of mechanics |
AS 2496-1981 | Breathing attachments for anaesthetic purposes for human use |
AS 2120.3-1992 | Medical suction equipment Suction equipment powered from a vacuum or pressure source (Reconfirmed 2016) |
AS 2472-1985 | Valves for medical gas cylinders |
AS/NZS 1715:2009 | Selection, use and maintenance of respiratory protective equipment (Reconfirmed 2024) |
AS/NZS 1716:2012 | Respiratory protective devices (Reconfirmed 2024) |
AS/NZS 1716:1994 | Respiratory protective devices |
AS/NZS 1716:2003 | Respiratory protective devices |
AS 3848.1-1999 | Filling of portable gas cylinders Decant filling of medical air and oxygen into portable cylinders - Safe procedures |
AS 1716-1991 | Respiratory protective devices |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.