• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

ISO 389-2:1994

Current

Current

The latest, up-to-date edition.

Acoustics Reference zero for the calibration of audiometric equipment Part 2: Reference equivalent threshold sound pressure levels for pure tones and insert earphones

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English, French

Published date

07-07-1994

£58.00
Excluding VAT

Specifies levels supplementary to those specified in ISO 389:1991 (to be re-issued as ISO 389-1). Values given are applicable to insert earphones of type Etymotic Research ER-3A, coupled to the human ear by ear inserts of type ER-3-14.

DocumentType
Standard
Pages
7
ProductNote
THIS STANDARD ALSO REFERS TO IEC 126:1973,IEC 711:1981, IEC 303:1970,IEC 318:1970
PublisherName
International Organization for Standardization
Status
Current

BS ISO 389-4 : 1994 AMD 10484 ACOUSTICS - REFERENCE ZERO FOR THE CALIBRATION OF AUDIOMETRIC EQUIPMENT - REFERENCE LEVELS FOR NARROWBAND MASKING NOISE
08/30189820 DC : DRAFT SEP 2008 BS EN ISO 8253-1 - ACOUSTICS - AUDIOMETRIC TEST METHODS - PART 1: BASIC PURE-TONE AIR AND BONE CONDUCTION THRESHOLD AUDIOMETRY
BS EN ISO 389-9:2009 Acoustics. Reference zero for the calibration of audiometric equipment Preferred test conditions for the determination of reference hearing threshold levels
BS EN 60318-5:2006 Electroacoustics. Simulators of human head and ear 2 cm<sup>3</sup> coupler for the measurement of hearing aids and earphones coupled to the ear by means of ear inserts
I.S. EN 15927:2010 SERVICES OFFERED BY HEARING AID PROFESSIONALS
IEC 60645-1:2017 Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone and speech audiometry
IEC 60318-5:2006 Electroacoustics - Simulators of human head and ear - Part 5: 2 cm<sup>3</sup> coupler for the measurement of hearing aids and earphones coupled to the ear by means of ear inserts
BS EN ISO 8253-1:2010 Acoustics. Audiometric test methods Pure-tone air and bone conduction audiometry
ISO 389-5:2006 Acoustics Reference zero for the calibration of audiometric equipment Part 5: Reference equivalent threshold sound pressure levels for pure tones in the frequency range 8 kHz to 16 kHz
EN 60645-5:2005 Electroacoustics - Audiometric equipment - Part 5: Instruments for the measurement of aural acoustic impedance/admittance
EN 60318-5 : 2006 ELECTROACOUSTICS - SIMULATORS OF HUMAN HEAD AND EAR - PART 5: 2 CM[3] COUPLER FOR THE MEASUREMENT OF HEARING AIDS AND EARPHONES COUPLED TO THE EAR BY MEANS OF EAR INSERTS
CEI EN 60318-4 : 2011 ELECTROACOUSTICS - SIMULATORS OF HUMAN HEAD AND EAR - PART 4: OCCLUDED-EAR SIMULATOR FOR THE MEASUREMENT OF EARPHONES COUPLED TO THE EAR BY MEANS OF EAR INSERTS
ANSI S3.6 : 2010 SPECIFICATION FOR AUDIOMETERS
04/30095174 DC : DRAFT JUN 2004 ISO 389-7 - ACOUSTICS - REFERENCE ZERO FOR THE CALIBRATION OF AUDIOMETRIC EQUIPMENT - PART 7: REFERENCE THRESHOLD OF HEARING UNDER FREE-FIELD AND DIFFUSE-FIELD LISTENING CONDITIONS
15/30297064 DC : DRAFT MAY 2015 BS ISO 7029 - ACOUSTICS - STATISTICAL DISTRIBUTION OF HEARING THRESHOLDS RELATED TO AGE AND GENDER
14/30313972 DC : 0 BS EN 60645-1 ED.4.0 - ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 1: EQUIPMENT FOR PURE-TONE AND SPEECH AUDIOMETRY
07/30173580 DC : 0 BS EN 60645-6 - ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 6: INSTRUMENTS FOR THE MEASUREMENT OF OTOACOUSTIC EMISSIONS
BS ISO 1999:2013 Acoustics. Estimation of noise-induced hearing loss
CEI EN 60645-1 : 2016 ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 1: EQUIPMENT FOR PURE-TONE AUDIOMETRY
UNI EN 15927 : 2010 SERVICES OFFERED BY HEARING AID PROFESSIONALS
EN 15927:2010 Services offered by hearing aid professionals
UNE-EN 15927:2011 Services offered by hearing aid professionals
UNI EN ISO 389-9 : 2009 ACOUSTICS - REFERENCE ZERO FOR THE CALIBRATION OF AUDIOMETRIC EQUIPMENT - PART 9: PREFERRED TEST CONDITIONS FOR THE DETERMINATION OF REFERENCE HEARING THRESHOLD LEVELS
CEI EN 60318-5 : 2007 ELECTROACOUSTICS - SIMULATORS OF HUMAN HEAD AND EAR - PART 5: 2 CM[3] COUPLER FOR THE MEASUREMENT OF HEARING AIDS AND EARPHONES COUPLED TO THE EAR BY MEANS OF EAR INSERTS
I.S. EN ISO 8253-1:2010 ACOUSTICS - AUDIOMETRIC TEST METHODS - PART 1: PURE-TONE AIR AND BONE CONDUCTION AUDIOMETRY
I.S. EN ISO 389-3:2016 ACOUSTICS - REFERENCE ZERO FOR THE CALIBRATION OF AUDIOMETRIC EQUIPMENT - PART 3: REFERENCE EQUIVALENT THRESHOLD VIBRATORY FORCE LEVELS FOR PURE TONES AND BONE VIBRATORS (ISO 389-3:2016)
I.S. EN ISO 389-5:2006 ACOUSTICS - REFERENCE ZERO FOR THE CALIBRATION OF AUDIOMETRIC EQUIPMENT - PART 5: REFERENCE EQUIVALENT THRESHOLD SOUND PRESSURE LEVELS FOR PURE TONES IN THE FREQUENCY RANGE 8 KHZ TO 16 KHZ
I.S. EN ISO 7029:2017 ACOUSTICS - STATISTICAL DISTRIBUTION OF HEARING THRESHOLDS RELATED TO AGE AND GENDER (ISO 7029:2017)
DIN EN ISO 389-9:2009-12 Acoustics - Reference zero for the calibration of audiometric equipment - Part 9: Preferred test conditions for the determination of reference hearing threshold levels (ISO 389-9:2009)
I.S. EN ISO 389-4:1999 ACOUSTICS - REFERENCE ZERO FOR THE CALIBRATION OF AUDIOMETRIC EQUIPMENT - PART 4: REFERENCE LEVELS FOR NARROW-BAND MASKING NOISE
BS EN 15927:2010 Services offered by hearing aid professionals
17/30333265 DC : 0 BS EN ISO 389-1 - ACOUSTICS - REFERENCE ZERO FOR THE CALIBRATION OF AUDIOMETRIC EQUIPMENT - PART 1: REFERENCE EQUIVALENT THRESHOLD SOUND PRESSURE LEVELS FOR PURE TONES AND SUPRA-AURAL EARPHONES
BS EN 60318-4:2010 Electroacoustics. Simulators of human head and ear Occluded-ear simulator for the measurement of earphones coupled to the ear by means of ear inserts
BS ISO 389-3 : 1994 AMD 10483 ACOUSTICS - REFERENCE ZERO FOR THE CALIBRATION OF AUDIOMETRIC EQUIPMENT - REFERENCE EQUIVALENT THRESHOLD FORCE LEVELS FOR PURE TOMES AND BONE VIBRATORS
15/30328565 DC : 0 BS EN 60645-1 ED4.0 - ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 1: EQUIPMENT FOR PURE-TONE AND SPEECH AUDIOMETRY
06/30160356 DC : 0 BS EN 60318-4 ED.1 - ELECTROACOUSTICS - SIMULATORS OF HUMAN HEAD AND EAR - OCCLUDED-EAR SIMULATOR FOR THE MEASUREMENT OF EARPHONES COUPLED TO THE EAR BY INSERT
I.S. EN 60645-1:2017 ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 1: EQUIPMENT FOR PURE-TONE AND SPEECH AUDIOMETRY
ANSI/ASA S3.55 PART 5:2014 Electroacoustics – Simulators of Human Head and Ear – Part 5: 2 cm3 Coupler for the Measurement of Hearing Aids and Earphones Coupled to the Ear by Means of Ear Inserts (a modified nationally adopted international standard)
UNE-EN ISO 389-3:2016 Acoustics - Reference zero for the calibration of audiometric equipment - Part 3: Reference equivalent threshold vibratory force levels for pure tones and bone vibrators (ISO 389-3:2016)
ISO 389-4:1994 Acoustics Reference zero for the calibration of audiometric equipment Part 4: Reference levels for narrow-band masking noise
UNE-EN ISO 8253-1:2011 Acoustics - Audiometric test methods - Part 1: Pure-tone air and bone conduction audiometry (ISO 8253-1:2010)
BS EN ISO 389-5:2006 Acoustics. Reference zero for the calibration of audiometric equipment Reference equivalent threshold sound pressure levels for pure tones in the frequency range 8 kHz to 16 kHz
IEC 60645-5:2004 Electroacoustics - Audiometric equipment - Part 5: Instruments for the measurement of aural acoustic impedance/admittance
ANSI/ASA S3.44 PART 1:2016(R2020) Acoustics – Estimation of Noise-induced Hearing Loss – Part 1: Method for Calculating Expected Noise-induced Permanent Threshold Shift (a modified nationally adopted international standard)
EN ISO 8253-1:2010 Acoustics - Audiometric test methods - Part 1: Pure-tone air and bone conduction audiometry (ISO 8253-1:2010)
EN ISO 389-3:2016 Acoustics - Reference zero for the calibration of audiometric equipment - Part 3: Reference equivalent threshold vibratory force levels for pure tones and bone vibrators (ISO 389-3:2016)
UNI EN ISO 8253-1 : 2010 ACOUSTICS - AUDIOMETRIC TEST METHODS - PART 1: PURE-TONE AIR AND BONE CONDUCTION AUDIOMETRY
04/30108702 DC : DRAFT FEB 2004 IEC 60318-5 - ELECTROACOUSTICS - SIMULATORS OF HUMAN HEAD AND HEAR - PART 5: 2 CM[3] COUPLER FOR THE MEASUREMENT OF HEARING AIDS AND EARPHONES COUPLED TO THE EAR BY MEANS OF EAR INSERTS
11/30218046 DC : 0 BS ISO 1999 - ACOUSTICS - ESTIMATION OF NOISE-INDUCED HEARING LOSS
07/30166205 DC : 0 BS ISO 389-9 - ACOUSTICS - REFERENCE ZERO FOR THE CALIBRATION OF AUDIOMETRIC EQUIPMENT - PART 9: PREFERRED TEST CONDITIONS FOR THE DETERMINATION OF REFERENCE HEARING THRESHOLD LEVELS
PD 6545:2005 Intended use of human head and ear simulators-guide
BS ISO TR 389-5 : 1998 AMD 12019 ACOUSTICS - REFERENCE ZERO FOR THE CALIBRATION OF AUDIOMETRIC EQUIPMENT - REFERENCE EQUIVALENT THRESHOLD SOUND PRESSURE LEVELS FOR PURE TONES IN THE FREQUENCY RANGE 9 KHZ TO 16 KHZ
08/30176438 DC : DRAFT JAN 2008 BS EN 60645-1 - ELECTRO ACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 1: PURE-TONE AUDIOMETERS
BS EN 60645-1:2017 Electroacoustics. Audiometric equipment Equipment for pure-tone and speech audiometry
BS EN 60645-5:2005 Electroacoustics. Audiometric equipment Instruments for the measurement of aural acoustic impedance/admittance
I.S. EN 60318-5:2006 ELECTROACOUSTICS - SIMULATORS OF HUMAN HEAD AND EAR - PART 5: 2 CM[3] COUPLER FOR THE MEASUREMENT OF HEARING AIDS AND EARPHONES COUPLED TO THE EAR BY MEANS OF EAR INSERTS
I.S. EN ISO 389-9:2009 ACOUSTICS - REFERENCE ZERO FOR THE CALIBRATION OF AUDIOMETRIC EQUIPMENT - PART 9: PREFERRED TEST CONDITIONS FOR THE DETERMINATION OF REFERENCE HEARING THRESHOLD LEVELS
I.S. EN 60318-4:2010 ELECTROACOUSTICS - SIMULATORS OF HUMAN HEAD AND EAR - PART 4: OCCLUDED-EAR SIMULATOR FOR THE MEASUREMENT OF EARPHONES COUPLED TO THE EAR BY MEANS OF EAR INSERTS
BS EN ISO 389-7 : 2005 ACOUSTICS - REFERENCE ZERO FOR THE CALIBRATION OF AUDIOMETRIC EQUIPMENT - PART 7: REFERENCE THRESHOLD OF HEARING UNDER FREE-FIELD AND DIFFUSE-FIELD LISTENING CONDITIONS (ISO 389-7:2005)
UNE-EN 60645-1:2015 Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone audiometry
IEC 60645-1:2017 RLV Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone and speech audiometry
ISO 389-9:2009 Acoustics Reference zero for the calibration of audiometric equipment Part 9: Preferred test conditions for the determination of reference hearing threshold levels
ISO 7029:2017 Acoustics — Statistical distribution of hearing thresholds related to age and gender
ISO 389-3:2016 Acoustics Reference zero for the calibration of audiometric equipment Part 3: Reference equivalent threshold vibratory force levels for pure tones and bone vibrators
BS EN ISO 7029:2017 Acoustics. Statistical distribution of hearing thresholds related to age and gender
IEC 60318-4:2010 Electroacoustics - Simulators of human head and ear - Part 4: Occluded-ear simulator for the measurement of earphones coupled to the ear by means of ear inserts
ISO/TR 389-5:1998 Acoustics Reference zero for the calibration of audiometric equipment Part 5: Reference equivalent threshold sound pressure levels for pure tones in the frequency range 8 kHz to 16 kHz
ISO 8253-1:2010 Acoustics Audiometric test methods Part 1: Pure-tone air and bone conduction audiometry
BS EN ISO 389-4:1999 Acoustics. Reference zero for the calibration of audiometric equipment Reference levels for narrow-band masking noise
BS EN ISO 389-3:2016 Acoustics. Reference zero for the calibration of audiometric equipment Reference equivalent threshold vibratory force levels for pure tones and bone vibrators
UNE-EN ISO 7029:2017 Acoustics - Statistical distribution of hearing thresholds related to age and gender (ISO 7029:2017)
EN ISO 389-5:2006 Acoustics - Reference zero for the calibration of audiometric equipment - Part 5: Reference equivalent threshold sound pressure levels for pure tones in the frequency range 8 kHz to 16 kHz (ISO 389-5:2006)
EN ISO 7029:2017 Acoustics - Statistical distribution of hearing thresholds related to age and gender (ISO 7029:2017)
EN ISO 389-9:2009 Acoustics - Reference zero for the calibration of audiometric equipment - Part 9: Preferred test conditions for the determination of reference hearing threshold levels (ISO 389-9:2009)
EN ISO 389-4:1998 Acoustics - Reference zero for the calibration of audiometric equipment - Part 4: Reference levels for narrow-band masking noise (ISO 389-4:1994)
14/30279048 DC : DRAFT OCT 2014 BS EN ISO 389-3 - ACOUSTICS - REFERENCE ZERO FOR THE CALIBRATION OF AUDIOMETRIC EQUIPMENT - PART 3: REFERENCE EQUIVALENT THRESHOLD FORCE LEVELS FOR PURE TONES AND BONE VIBRATORS
ISO 1999:2013 Acoustics Estimation of noise-induced hearing loss
CEI EN 60645-5 : 2006 ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 5: INSTRUMENTS FOR THE MEASUREMENT OF AURAL ACOUSTIC IMPEDANCE/ADMITTANCE
ANSI/ASA S3.44 PART 1 : 2016 Acoustics – Estimation of Noise-induced Hearing Loss – Part 1: Method for Calculating Expected Noise-induced Permanent Threshold Shift (a modified nationally adopted international standard)<br>
I.S. EN 60645-5:2005 ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 5: INSTRUMENTS FOR THE MEASUREMENT OF AURAL ACOUSTIC IMPEDANCE/ADMITTANCE
I.S. EN ISO 389-7:2005 ACOUSTICS - REFERENCE ZERO FOR THE CALIBRATION OF AUDIOMETRIC EQUIPMENT - PART 7: REFERENCE THRESHOLD OF HEARING UNDER FREE-FIELD AND DIFFUSE-FIELD LISTENING CONDITIONS
ISO 389-7:2005 Acoustics Reference zero for the calibration of audiometric equipment Part 7: Reference threshold of hearing under free-field and diffuse-field listening conditions
EN 60318-4:2010 Electroacoustics - Simulators of human head and ear - Part 4: Occluded-ear simulator for the measurement of earphones coupled to the ear by means of ear inserts
DIN EN ISO 389-5:2007-05 Acoustics - Reference zero for the calibration of audiometric equipment - Part 5: Reference equivalent threshold sound pressure levels for pure tones in the frequency range 8 kHz to 16 kHz (ISO 389-5:2006)
DIN EN ISO 389-7:1998-12 ACOUSTICS - REFERENCE ZERO FOR THE CALIBRATION OF AUDIOMETRIC EQUIPMENT - PART 7: REFERENCE THRESHOLD OF HEARING UNDER FREE-FIELD AND DIFFUSE-FIELD LISTENING CONDITIONS
EN 60645-1:2017 Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone and speech audiometry

ISO 389-4:1994 Acoustics Reference zero for the calibration of audiometric equipment Part 4: Reference levels for narrow-band masking noise
ISO 389:1991 Acoustics Standard reference zero for the calibration of pure-tone air conduction audiometers
IEC 60126:1973 IEC reference coupler for the measurement of hearing aids using earphones coupled to the ear by means of ear inserts
IEC 60711:1981 Occluded-ear simulator for the measurement of earphones coupled to the ear by ear inserts
IEC 60318:1970 An IEC artificial ear, of the wide band type, for the calibration of earphones used in audiometry
AS/NZS ISO 8253.1:2019 Acoustics - Audiometric test methods Pure-tone air and bone conduction audiometry
AS ISO 7029:2019 Acoustics - Statistical distribution of hearing thresholds related to age and gender

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.