• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

BS 4553-2:1998

Current

Current

The latest, up-to-date edition.

Specification for 600/1000 V single-phase split concentric electric cables Cables having thermosetting insulation

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

29-04-2005

£134.00
Excluding VAT

Committees responsible
Foreword
1 Scope
2 Normative references
3 Definitions
4 Voltage designation
5 Phase conductor
6 Insulation
7 Identification of phase core
8 Bedding
9 Concentric layer
10 Binders
11 Oversheath
12 Cable marking
13 End sealing
14 Schedule of tests
15 Test conditions
16 Routine tests
17 Sample tests
18 Type tests
Annex A (informative) Recommendations for the selection
        and operation of cables
Annex B (informative) Recommendations for installations of
        cables
Annex C (informative) Information to be provided with enquiry
        or order
Annex D (normative) Measurement of thickness
Annex E (normative) Voltage tests on completed cables
Annex F (Spare)
Annex G (normative) Compatibility test
Annex H (informative) Notes on type tests
Annex J (informative) Guide to use
Bibliography

Construction requirements and methods of tests for cables intended for use in fixed installations in industrial areas, buildings and similar applications. For use where current loading gives conductor temperature rise not exceeding 90°C and where maximum short circuit conductor temperature is 250°C.

Committee
GEL/20/17
DevelopmentNote
Together with BS 4553-1(1998) & BS 4553-3(1998), Supersedes 97/201035 DC & 02/206315 DC (02/2004) Reviewed and confirmed by BSI, January 2012. (12/2011)
DocumentType
Standard
Pages
20
PublisherName
British Standards Institution
Status
Current
Supersedes

This British Standard specifies requirements for construction and gives methods of test for XLPE-insulated single-phase split concentric cables for operation on an earthed neutral system at nominal voltages up to and including 1 000 V between phases and 600 V to earth.

The cables specified in this part of BS 4553 have a central phase conductor insulated with XLPE and a concentric layer comprising bare copper wires (earth continuity conductor) and copper wires covered with extruded polymer (neutral conductor). The cables are intended for use in fixed installations in industrial areas, buildings and similar applications. They are suitable for use in situations where the combination of ambient temperature and temperature rise due to loading current results in a conductor temperature not exceeding 90 °C and for a maximum short-circuit conductor temperature of 250 °C.

NOTE 1 Limitation on the temperature of the cables may be imposed in situations where they may be touched.

NOTE 2 Due to the relatively high conductor temperature, there is a risk of drying out the surrounding soil causing an increase in thermal resistivity which in turn would lead to the cable temperature rising to a higher value than anticipated. For cable laid directly in the ground, a suitable de-rating factor should be applied or a lower maximum sustained conductor operating temperature should be assumed to take into account the possible effects of soil drying out.

NOTE 3 In installations which include cable joints and terminations, the performance of these accessories should be taken into account in deciding the maximum operating temperature of the cable.

Guidance concerning selection, installation and usage is given in Annex A, Annex B and Annex J respectively.

BS 4727-2:GRP08(1994) : 1994 GLOSSARY OF ELECTROTECHNICAL, POWER, TELECOMMUNICATION, ELECTRONICS, LIGHTING AND COLOUR TERMS - TERMS PARTICULAR TO POWER ENGINEERING - ELECTRIC CABLES
BS EN 60811-1-1:1995 Insulating and sheathing materials of electric cables. Common test methods. General application Measurement of thickness and overall dimensions. Tests for determining the mechanical properties - Section 1: Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
BS EN 60811-1-3:1995 Insulating and sheathing materials of electric cables. Common test methods. General application Methods for determining the density. Water absorption tests. Shrinkage test
BS EN 60079-14:2014 Explosive atmospheres Electrical installations design, selection and erection
BS 7671(2001) : 2001 AMD 14905 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS
IEC 60183:2015 Guidance for the selection of high-voltage A.C. cable systems
BS EN 60811-1-2:1995 Insulating and sheathing materials of electric cables. Common test methods. General application Thermal ageing methods

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.