MIL-HDBK-423 Base Document:1993
Current
The latest, up-to-date edition.
High-Altitude Electromagnetic Pulse (HEMP) Protection for Fixed and Transportable Ground - Based C4 1 Facilities - Volume 1 - Fixed Facilities
15-05-1993
Provides information to managers and engineers responsible for the design, construction, testing, and hardness maintenance/hardness surveillance of fixed and transportable ground-based facilities that must be hardened against the high altitude electromagnetic pulse (HEMP).
| DocumentType |
Standard
|
| PublisherName |
US Military Specs/Standards/Handbooks
|
| Status |
Current
|
MIL-HDBK-423 handbook provides information to managers and engineers responsible for the design, construction, testing, and hardness maintenance/hardness surveillance of fixed and transportable ground-based facilities that must be hardened against the high altitude electromagnetic pulse (HEMP). The primary purpose of this Volume I is to provide detailed guidance to implement HEMP protection of fixed facilities in accordance with requirements of MIL-SDT-188-125, \"High Altitude Electromagnetic Pulse (HEMP) Protection for Ground-Based C\'I Facilities Performing Critical, Time Urgent Missions.\"
| UFC 3-501-01 : 2015 | UNIFIED FACILITIES CRITERIA - ELECTRICAL ENGINEERING |
| MIL-STD-188-125-1 Base Document:1998 | High-Altitude Electromagnetic Pulse (HEMP) Protection for Ground-Based Facilities Performing Critical, Time-Urgent Missions Part 1 Fixed Facilities |
| FC 4-218-01F : 2015 | FACILITIES CRITERIA - AIR FORCE CRITERIA FOR PRECISION MEASUREMENT EQUIPMENT LABORATORY DESIGN AND CONSTRUCTION |
| DEFSTAN 59-188(PT1)/1(2009) : 2009 | HIGH ALTITUDE ELECTROMAGNETIC PULSE (HEMP) PROTECTION FOR GROUND BASED COMMUNICATION FACILITIES PERFORMING CRITICAL, TIME-URGENT MISSIONS - PART 1: FIXED FACILITIES |
| MIL-STD-461 Revision G:2015 | Requirements for the Control of Electromagnetic Interference Characteristics of Subsystems and Equipment |
| MIL-STD-464 Revision C:2010 | Electromagnetic Environmental Effects Requirements for Systems |
| DEFSTAN 59-188(PT2)/1(2010) : 2010 | HIGH ALTITUDE ELECTROMAGNETIC PULSE (HEMP) PROTECTION FOR GROUND BASED COMMUNICATION FACILITIES PERFORMING CRITICAL, TIME-URGENT MISSIONS - PART 2: TRANSPORTABLE AND MOBILE SYSTEMS |
| DEFSTAN 59-188(PT2)/2(2017) : 2017 | HIGH ALTITUDE ELECTROMAGNETIC PULSE (HEMP) PROTECTION FOR GROUND BASED COMMUNICATION FACILITIES PERFORMING CRITICAL, TIME-URGENT MISSIONS - PART 2: TRANSPORTABLE AND MOBILE SYSTEMS |
| DEFSTAN 59-188(PT1)/2(2014) : 2014 | HIGH ALTITUDE ELECTROMAGNETIC PULSE (HEMP) PROTECTION FOR GROUND BASED COMMUNICATION FACILITIES PERFORMING CRITICAL, TIME-URGENT MISSIONS - PART 1: FIXED FACILITIES |
| MIL-STD-188-125-2 Base Document:1999 | High-Altitude Electromagnetic Pulse (HEMP) Protection for Ground-Based Facilities Performing Critical, Time-Urgent Missions Part 2 - Transportable Systems |
| AECTP-500 : 2016 | ELECTROMAGNETIC ENVIRONMENTAL EFFECTS TESTS AND VERIFICATION |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-