IEC 61897:1998
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Overhead lines - Requirements and tests for Stockbridge type aeolian vibration dampers
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
12-09-2022
English - French, Spanish, Castilian
11-09-1998
FOREWORD
1 Scope
2 Normative references
3 Definitions
4 General requirements
4.1 Design
4.2 Materials
4.3 Mass, dimensions and tolerances
4.4 Protection against corrosion
4.5 Manufacturing appearance and finish
4.6 Marking
4.7 Installation instructions
5 Quality assurance
6 Classification of tests
6.1 Type tests
6.1.1 General
6.1.2 Application
6.2 Sample tests
6.2.1 General
6.2.2 Application
6.2.3 Sampling, acceptance criteria
6.3 Routine tests
6.3.1 General
6.3.2 Application and acceptance criteria
6.4 Table of tests to be applied
7 Test methods
7.1 Visual examination
7.2 Verification of dimensions, materials and mass
7.3 Corrosion protection tests
7.3.1 Hot dip galvanized components (other
than messenger cable wires)
7.3.2 Ferrous components protected from
corrosion by methods other than hot
dip galvanizing
7.3.3 Hot dip galvanized messenger cable
wires
7.4 Non-destructive tests
7.5 Clamp slip test
7.6 Breakaway bolt test
7.7 Clamp bolt tightening test
7.8 Attachment of weights to messenger cable
7.9 Attachment of clamp to messenger cable test
7.10 Corona and radio interference voltage (RIV)
tests
7.11 Damper performance tests
7.11.1 Performance test variants
7.11.2 Damper characteristic test
7.11.3 Damper effectiveness evaluation
7.11.3.1 Method of evaluation
7.11.3.2 Laboratory test
7.11.3.3 Field test
7.11.3.4 Analytical method
7.12 Damper fatigue test
7.12.1 Test methods
7.12.2 Swept frequency method
7.12.3 Resonant frequency method
7.12.4 Acceptance criteria
Annex A (normative) Minimum technical details to be agreed
between purchaser and supplier
Annex B (informative) Examples of graphs relevant to damper
characteristic test
Annex C (normative) Wind power input curve
Bibliography
Applies to Stockbridge type aeolian vibration dampers intended for single conductors or earth wires or conductor bundles where dampers are direclty attached to each subconductor.
Committee |
TC 11
|
DevelopmentNote |
Also numbered as BS EN 61897. (09/2005) Stability Date: 2017. (09/2017)
|
DocumentType |
Standard
|
Pages |
45
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
CEI EN 61897 : 1999 | Identical |
SN EN 61897 : 1998 | Identical |
EN 61897:1998 | Identical |
PN EN 61897 : DEC 2002 | Identical |
NEN EN IEC 61897 : 1999 | Identical |
I.S. EN 61897:1999 | Identical |
VDE 0212-3 : 1999 | Identical |
DIN EN 61897 : 1999 | Identical |
NF EN 61897 : 2001 | Identical |
OVE/ONORM EN 61897 : 1999 | Identical |
UNE-EN 61897:2000 | Identical |
IEEE 1591.1-2012 | IEEE Standard for Testing and Performance of Hardware for Optical Ground Wire (OPGW) |
IEEE 1591.2-2017 | IEEE Standard for Testing and Performance of Hardware for All-Dielectric Self-Supporting (ADSS) Fiber Optic Cable |
BS EN 50341-1:2012 | Overhead electrical lines exceeding AC 1 kV General requirements. Common specifications |
I.S. EN 50341-1:2012 | OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS |
EN 50341-1:2012 | Overhead electrical lines exceeding AC 1 kV - Part 1: General requirements - Common specifications |
CEI EN 50341-1 : 2013 | OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS |
12/30260570 DC : 0 | BS EN 50341-1 - OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS |
PREN 50341-1 : DRAFT 2012 | OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS |
ISO 3951:1989 | Sampling procedures and charts for inspection by variables for percent nonconforming |
ISO 1461:2009 | Hot dip galvanized coatings on fabricated iron and steel articles — Specifications and test methods |
IEC 60888:1987 | Zinc-coated steel wires for stranded conductors |
ISO 2859-2:1985 | Sampling procedures for inspection by attributes — Part 2: Sampling plans indexed by limiting quality (LQ) for isolated lot inspection |
IEC 60050-466:1990 | International Electrotechnical Vocabulary (IEV) - Part 466: Overhead lines |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.