IEC 60888:1987
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
Zinc-coated steel wires for stranded conductors
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
04-03-2022
English - French, English, French
30-12-1987
Foreword
Preface
1. Scope
2. Values for zinc-coated steel wires
3. Material
4. Freedom from defects
5. Diameter and tolerance on diameter
6. Length and tolerance on length
7. Joints
8. Sampling
9. Place of testing
10. Mechanical tests
10.1 Stress at 1% extension
10.2 Tensile test
10.3 Ductility test
11. Zinc coating test
11.1 Determination of mass of zinc coating
11.2 Gas volumetric method
11.3 Gravimetric method
11.4 Test for adherence of zinc coating
11.5 Continuity of coating
12. Certificate of coating
Appendix A - Gas volumetric method for determining mass of zinc
coating
Appendix B - Gravimetric method for determining mass of zinc
coating
Applies to zinc-coated steel wires used in the construction and/or reinforcement of conductors for overhead power transmission purposes, and is intended to cover all wires used in construction where the individual wire diameters, including coating, are in the range of 1.25 mm to 5.50 mm. Three grades of steel are included to reflect the needs of conductor users: regular steel, high strength steel and extra high strength steel. Two classes of coating represented by minimum zinc mass per unit area are included: Class 1 and Class 2.
DevelopmentNote |
Stability date: 2019. (09/2017)
|
DocumentType |
Standard
|
Pages |
25
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
Standards | Relationship |
NFC 34 113 : 1992 | Similar to |
BS 4565:1990 | Similar to |
UNE 21005:1991 | Identical |
15/30320892 DC : 0 | BS EN 60794-4 - OPTICAL FIBRE CABLES - PART 4: SECTIONAL SPECIFICATION - AERIAL OPTICAL CABLES ALONG ELECTRICAL POWER LINES |
I.S. EN 60794-4-10:2014 | OPTICAL FIBRE CABLES - PART 4-10: FAMILY SPECIFICATION - OPTICAL GROUND WIRES (OPGW) ALONG ELECTRICAL POWER LINES |
VDE 0212-2 : 1999 | OVERHEAD LINES - REQUIREMENTS AND TESTS FOR SPACERS |
97/202499 DC : 0 | |
02/205756 DC : DRAFT MAY 2002 | IEC 60794-4. ED 2.0 - OPTICAL FIBRE CABLES - PART 4: SECTIONAL SPECIFICATION - AERIAL OPTICAL CABLES ALONG ELECTRICAL POWER LINES |
CEI EN 61897 : 1999 | OVERHEAD LINES - REQUIREMENTS AND TESTS FOR STOCKBRIDGE TYPE AEOLIAN VIBRATION DAMPERS |
BS EN 62420:2008 | Concentric lay stranded overhead electrical conductors containing one or more gap(s) |
BS EN 60794-4-10:2014 | Optical fibre cables Family specification. Optical ground wires (OPGW) along electrical power lines |
CEI EN 62420 : 2009 | CONCENTRIC LAY STRANDED OVERHEAD ELECTRICAL CONDUCTORS CONTAINING ONE OR MORE GAP(S) |
VDE 0212-3 : 1999 | OVERHEAD LINES - REQUIREMENTS AND TESTS FOR STOCKBRIDGE TYPE AEOLIAN VIBRATION DAMPERS |
HD 620 : 2010 | DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV |
EN 60794-4:2003 | Optical fibre cables - Part 4: Sectional specification - Aerial optical cables along electrical power lines |
BS EN 61854:1998 | Overhead lines. Requirements and tests for spacers |
CEI EN 62219 : 2002 | OVERHEAD ELECTRICAL CONDUCTORS - FORMED WIRE, CONCENTRIC LAY, STRANDED CONDUCTORS |
NF EN 61854 : 2001 | OVERHEAD LINES - REQUIREMENTS AND TESTS FOR SPACERS |
CEI EN 61854 : 2000 | OVERHEAD LINES - REQUIREMENTS AND TESTS FOR SPACERS |
I.S. EN 61897:1999 | OVERHEAD LINES - REQUIREMENTS AND TESTS FOR STOCKBRIDGE TYPE AEOLIAN VIBRATION DAMPERS |
I.S. EN 62420:2008 | CONCENTRIC LAY STRANDED OVERHEAD ELECTRICAL CONDUCTORS CONTAINING ONE OR MORE GAP(S) |
IEC 60794-4:2003 | Optical fibre cables - Part 4: Sectional specification - Aerial optical cables along electrical power lines |
EN 61854:1998 | Overhead lines - Requirements and tests for spacers |
IEC 61897:1998 | Overhead lines - Requirements and tests for Stockbridge type aeolian vibration dampers |
DIN EN 61897 : 1999 | OVERHEAD LINES - REQUIREMENTS AND TESTS FOR STOCKBRIDGE TYPE AEOLIAN VIBRATION DAMPERS |
06/30156083 DC : DRAFT SEP 2006 | BS EN 62420 - CONCENTRIC LAY STRANDED OVERHEAD ELECTRICAL CONDUCTORS CONTAINING ONE OR GAP(S) |
DIN EN 61854 : 1999 | OVERHEAD LINES - REQUIREMENTS AND TESTS FOR SPACERS |
I.S. EN 60794-4:2003 | OPTICAL FIBRE CABLES - PART 4: SECTIONAL SPECIFICATION - AERIAL OPTICAL CABLES ALONG ELECTRICAL POWER LINES |
I.S. EN 61854:1999 | OVERHEAD LINES - REQUIREMENTS AND TESTS FOR SPACERS |
NF EN 62420 : 2011 | CONCENTRIC LAY STRANDED OVERHEAD ELECTRICAL CONDUCTORS CONTAINING ONE OR MORE GAP(S) |
I.S. HD 620:2010 | DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV |
IEC 61854:1998 | Overhead lines - Requirements and tests for spacers |
IEC 60794-4-10:2014 | Optical fibre cables - Part 4-10: Family specification - Optical ground wires (OPGW) along electrical power lines |
IEC 62420:2008 | Concentric lay stranded overhead electrical conductors containing one or more gap(s) |
EN 60794-4-10:2014 | Optical fibre cables - Part 4-10: Family specification - Optical ground wires (OPGW) along electrical power lines |
NF EN 61897 : 2001 | OVERHEAD LINES - REQUIREMENTS AND TESTS FOR STOCKBRIDGE TYPE AEOLIAN VIBRATION DAMPERS |
BS EN 61897:1999 | Overhead lines. Requirements and tests for Stockbridge type aeolian vibration dampers |
13/30292534 DC : 0 | BS EN 60794-4-10 ED 2.0 - OPTICAL FIBRE CABLES - PART 4-10: FAMILY SPECIFICATION - OPGW (OPTICAL GROUND WIRES) ALONG ELECTRICAL POWER LINES |
BS EN 62219:2002 | Overhead electrical conductors. Formed wire, concentric lay, stranded conductors |
I.S. EN 62219:2002 | OVERHEAD ELECTRICAL CONDUCTORS - FORMED WIRE, CONCENTRIC LAY, STRANDED CONDUCTORS |
BS EN 60794-4:2003 | Optical fibre cables Sectional specification. Aerial optical cables along electrical power lines |
NF EN 60794-4 : 2004 | OPTICAL FIBER CABLES - PART 4: SECTIONAL SPECIFICATION - AERIAL OPTICAL CABLES ALONG ELECTRICAL POWER LINES |
BS EN 61232:1997 | Aluminium-clad steel wires for electrical purposes |
EN 61897:1998 | Overhead lines - Requirements and tests for Stockbridge type aeolian vibration dampers |
IEC 62219:2002 | Overhead electrical conductors - Formed wire, concentric lay, stranded conductors |
EN 62219:2002 | Overhead electrical conductors - Formed wire, concentric lay, stranded conductors |
EN 62420:2008 | Concentric lay stranded overhead electrical conductors containing one or more gap(s) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.