Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

EN 14989-2:2007

Current

Current

The latest, up-to-date edition.

Chimneys - Requirements and test methods for metal chimneys and material independent air supply ducts for roomsealed heating applications - Part 2: Flue and air supply ducts for room sealed appliances

Published date

12-12-2007

Sorry this product is not available in your region.

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 Manufacturer's declaration for type testing
6 Dimensions and tolerances
7 Performance requirements
   7.1 General
   7.2 Mechanical resistance and stability
       7.2.1 Compressive strength
       7.2.2 Tensile strength
       7.2.3 Lateral strength
   7.3 Resistance to fire
       7.3.1 Internal to external
       7.3.2 External to external
   7.4 Hygiene, health and environment
       7.4.1 Gastightness of the flue duct
       7.4.2 Gastightness of the air supply duct
   7.5 Safety in use
       7.5.1 Thermal performance
       7.5.2 Thermal resistance
       7.5.3 Rainwater ingress
       7.5.4 Flow resistance of the flue and air supply ducts
             and fittings
       7.5.5 Water vapour diffusion resistance
       7.5.6 Condensate penetration resistance
   7.6 Materials
       7.6.1 Flue ducts and other parts in contact with combustion
             products
       7.6.2 Air supply duct and other parts not in contact with
             combustion products
       7.6.3 Additional information on plastics and elastomers
       7.6.4 Freeze/thaw
8 Product information
   8.1 Manufacturer's instructions
   8.2 Minimum information to be included in the manufacturer's
       instructions
   8.3 Appliance adapter
9 Marking
   9.1 General
   9.2 Flue and air supply duct
   9.3 Packaging
   9.4 Chimney plate
10 Designation
   10.1 General
   10.2 Temperature classes and test temperature
   10.3 Pressure class
   10.4 Condensate resistance class
   10.5 Corrosion resistance
        10.5.1 Corrosion resistance
        10.5.2 Flue duct material specification
   10.6 Resistance to fire - Soot fire resistance, and distance
        to combustible material
11 Evaluation of conformity
   11.1 General
   11.2 Type testing
        11.2.1 Initial type testing (ITT)
        11.2.2 Further type testing
        11.2.3 Sampling for type testing
   11.3 Factory production control (FPC)
        11.3.1 General
        11.3.2 Equipment
        11.3.3 Raw materials and components
        11.3.4 Product testing and evaluation
        11.3.5 Non conforming products
12 Test methods
   12.1 Mechanical resistance and stability
        12.1.1 Compressive strength
        12.1.2 Tensile strength
        12.1.3 Lateral strength
   12.2 Hygiene, health and environment
        12.2.1 Gastightness
   12.3 Safety in use
        12.3.1 Thermal performance
        12.3.2 Thermal resistance
        12.3.3 Rainwater ingress
        12.3.4 Flow resistance of the flue and air supply ducts
        12.3.5 Vapour and condensate resistance test
        12.3.6 Condensate resistance test
   12.4 Low temperature test
Annex A (informative) - Preferred dimensions
      A.1 General
      A.2 Dimensions of the push-in spigots for a separate
          air/flue configuration
      A.3 Dimensions of the push-in spigots for a concentric
          air/flue configuration
Annex B (normative) - Coefficients of flow resistance
Annex C (normative) - Choice of size for type test and sampling
Annex D (normative) - Sampling for factory production control
      D.1 Incoming material
          D.1.1 Sampling plans
          D.1.2 Acceptable quality level (AQL)
          D.1.3 Normal, tightened or reduced inspection
          D.1.4 Single, double, multiple or sequential sampling
          D.1.5 Batch quantity
          D.1.6 The inspection level
      D.2 In-process inspection
          D.2.1 All dimensional aspects
          D.2.2 Joint leakage tests
          D.2.3 Insulation weight checks
          D.2.4 Volume and density checks
          D.2.5 Finished goods checks
Annex E (normative) - Factory production control
      E.1 Insulation material
      E.2 Metals, including coatings
      E.3 Supports
      E.4 Seals and sealants
      E.5 Manufacturing checks
          E.5.1 Dimensions
          E.5.2 Other checks
Annex ZA (informative) - Clauses of this European Standard
         addressing the provisions of the EU Construction
         Products Directive
      ZA.1 Scope and relevant characteristics
      ZA.2 Procedure for attestation of conformity of metal
           liners, connecting flue pipes and fittings flue and
           material independent air supply ducts for room sealed
           appliances
           ZA.2.1 System of attestation of conformity
           ZA.2.2 EC Declaration of conformity
      ZA.3 CE marking and labelling
Bibliography

This European Standard specifies requirements and test methods for metal flue ducts material independent air supply ducts for room sealed appliances.It also specifies the requirements for marking, manufacturer's instruction, product information and evaluation of conformity.NOTE 1Recommendations for preferred dimensions of products are given in the informative Annex A.NOTE 2In this European Standard, only general requirements are specified for elastomeric and plastic components. Elastomeric and plastic products used in flue systems are covered by separate standards, i.e. EN 14241-1 and EN 14471.nformity.

Committee
CEN/TC 166
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current

PREN 15250 : DRAFT 2012 SLOW HEAT RELEASE APPLIANCES FIRED BY SOLID FUEL - REQUIREMENTS AND TEST METHODS
17/30353865 DC : 0 BS EN 1443 - CHIMNEYS - GENERAL REQUIREMENTS
17/30339852 DC : 0 BS EN 1366-13 - FIRE RESISTANCE TESTS FOR SERVICE INSTALLATIONS - PART 13: CHIMNEYS
UNI EN 15287-2 : 2008 CHIMNEYS - DESIGN, INSTALLATION AND COMMISSIONING OF CHIMNEYS - PART 2: CHIMNEYS FOR ROOM-SEALED APPLIANCES
BS EN 15287-2:2008 Chimneys. Design, installation and commissioning of chimneys Chimneys for roomsealed appliances
PREN 1443 : DRAFT 2017 CHIMNEYS - GENERAL REQUIREMENTS
12/30260516 DC BS EN 15250 - SLOW HEAT RELEASE APPLIANCES FIRED BY SOLID FUEL - REQUIREMENTS AND TEST METHODS
I.S. EN 15287-2:2008 CHIMNEYS - DESIGN, INSTALLATION AND COMMISSIONING OF CHIMNEYS - PART 2: CHIMNEYS FOR ROOMSEALED APPLIANCES
13/30271701 DC : 0 BS EN 16510-1 - RESIDENTIAL SOLID FUEL BURNING APPLIANCES - PART 1: GENERAL REQUIREMENTS AND TEST METHODS
EN 15287-2:2008 Chimneys - Design, installation and commissioning of chimneys - Part 2: Chimneys for roomsealed appliances
DIN EN 15287-2:2008-06 Chimneys - Design, installation and commissioning of chimneys - Part 2: Chimneys for roomsealed appliances
PREN 16510-1 : DRAFT 2013 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - PART 1: GENERAL REQUIREMENTS AND TEST METHODS

93/68/EEC : 1993 AMD 2 1998 COUNCIL DIRECTIVE 93/68/EEC OF 22.7.93 AMENDING DIRECTIVES 87/404/EEC, 88/378/EEC, 89/106/EEC, 89/336/EEC, 89/392/EEC, 89/686/EEC, 90/384/EEC, 90/385/EEC, 90/396/EEC, 91/263/EEC, 92/42/EEC AND 73/23/EEC
EN 1859:2009+A1:2013 Chimneys - Metal chimneys - Test methods
EN 1856-2:2009 Chimneys - Requirements for metal chimneys - Part 2: Metal flue liners and connecting flue pipes
ISO 13732-1:2006 Ergonomics of the thermal environment — Methods for the assessment of human responses to contact with surfaces — Part 1: Hot surfaces
89/106/EEC : 1988 COUNCIL DIRECTIVE OF 21 DECEMBER 1988 ON THE APPROXIMATION OF LAWS, REGULATIONS AND ADMINISTRATIVE PROVISIONS OF THE MEMBER STATES RELATING TO CONSTRUCTION PRODUCTS
EN 13216-1:2004 Chimneys - Test methods for system chimneys - Part 1: General test methods
EN ISO 13732-1:2008 Ergonomics of the thermal environment - Methods for the assessment of human responses to contact with surfaces - Part 1: Hot surfaces (ISO 13732-1:2006)
EN 14241-1:2013 Chimneys - Elastomeric seals and elastomeric sealants - Material requirements and test methods - Part 1: Seals in flue liners
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
EN 14471:2013+A1:2015 Chimneys - System chimneys with plastic flue liners - Requirements and test methods
BS 1042-2.1:1983 Measurement of fluid flow in closed conduits. Velocity area methods Method using Pitot static tubes
EN 1443:2003 Chimneys - General requirements
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
EN 1856-1:2009 Chimneys - Requirements for metal chimneys - Part 1: System chimney products
EN 10088-1:2014 Stainless steels - Part 1: List of stainless steels

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.