EN 13959:2004
Current
The latest, up-to-date edition.
Anti-pollution check valves - DN 6 to DN 250 inclusive family E, type A, B, C and D
20-10-2004
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
3.1 Anti-pollution check valves
3.2 Flanged anti-pollution check valves; class a and
class b
3.3 Combined product
4 Nominal size
5 Designation
6 Marking and technical documents
6.1 Marking
6.2 Technical documents
7 Symbolization
8 General design characteristics
8.1 Overall length and diameters of check valves
8.2 End connections
8.3 Test and drain ports
8.4 Other characteristics
9 Physio-chemical characteristics
9.1 Materials
9.2 Nature of materials
10 Test Arrangements
10.1 Sequence of testing
10.2 Apparatus
11 Hydraulic and mechanical characteristics
11.1 High velocity (stage 1)
11.2 Flow rate/pressure loss (stage 2)
11.3 Mechanical strength of the body (stage 3)
11.4 Bending moment (stage 4)
11.5 Pressure tightness under a low reverse pressure
differential (stage 5)
11.6 Pressure tightness under a high reverse pressure
and verification that the check valve has not
jammed (stage 6)
11.7 Pressure differential at which the check valve
closes (stage 7)
11.8 Compatibility with products used for disinfection
of networks (stage 8)
11.9 Endurance (stage 9)
11.10 Pressure tightness under a low reverse pressure
differential (stage 10)
11.11 Pressure tightness under a high reverse pressure
and verification that the check valve has not
jammed (stage 11)
11.12 Pressure differential at which the check valve
closes (stage 12)
12 General working characteristics
12.1 Resistance to corrosion
12.2 Acoustic characteristics
13 Presentation at delivery
Annex A (informative) Numbers of test devices/tests
The purpose of this European Standard is to specify:
-field of application of Anti-pollution Check Valves;
-backflow prevention properties, dimensional and physio-chemical properties, and properties of general hydraulic, mechanical and acoustic design to which Anti-pollution Check Valves of nominal sizes DN 6 to DN 250 inclusive shall conform;
-Family E, type A, controllable Anti-pollution Check Valve (with test port);
-Family E, type B, non-controllable Anti-pollution Check Valve, including Cartridge Check Valve;
-Family E, type C, controllable Anti-pollution Double Check Valve (with test ports);
-Family E, type D, non-controllable Anti-pollution Double Check Valve, including Cartridge Double Check Valve;
-test procedures and requirements for verifying the backflow protection properties of stop valves, draw-off taps etc. which incorporate a check valve function. Stop valves, draw off taps etc, need also to comply with a recognised standard;
-marking;
-presentation at delivery.
This standard specifies the characteristics of Anti-pollution Check Valves of DN 6 up to and including DN 250 that are suitable for use in drinking water systems. For application feasibility see Table 1.
Table 1 - Nominal size vs Conditions of use
Nominalsize(DN)Max. OperatingtemperatureMax. Operating pressureInstallation
DN 50 65 °C 1 000 kPa (10 bar) Horizontal only
Anti-pollution Check Valves covered by this standard are of Pressure Class PN 10.
The field of application of EN 1717 is limited to 10 bar, flanges could be drilled in PN 16 pattern.
Anti-pollution Check Valves of PN 16 shall satisfy the requirements of standard EN 13959 and comply with tests which characterise the PN of the device.
Committee |
CEN/TC 164
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
UNE-EN 13959:2005 | Identical |
NBN EN 13959 : 2004 | Identical |
PN EN 13959 : 2005 | Identical |
BS EN 13959:2004 | Identical |
UNI EN 13959 : 2005 | Identical |
NS EN 13959 : 1ED 2005 | Identical |
NF EN 13959 : 2005 | Identical |
NEN EN 13959 : 2004 | Identical |
I.S. EN 13959:2004 | Identical |
SN EN 13959 : 2004 | Identical |
DIN EN 13959:2005-01 | Identical |
13/30268239 DC : 0 | BS EN 1487 - BUILDING VALVES - HYDAULIC SAFETY GROUPS - TESTS AND REQUIREMENTS |
BS EN ISO 26722:2015 | Water treatment equipment for haemodialysis applications and related therapies |
PREN 1487 : DRAFT 2012 | BUILDING VALVES - HYDAULIC SAFETY GROUPS - TESTS AND REQUIREMENTS |
NF EN 806-5 : 2012 | SPECIFICATION FOR INSTALLATIONS INSIDE BUILDINGS CONVEYING WATER FOR HUMAN CONSUMPTION - PART 5: OPERATION AND MAINTENANCE |
02/103309 DC : DRAFT MAY 2002 | BS EN 14455 - DEVICES TO PREVENT POLLUTION BY BLACKFLOW OF POTABLE WATER - PRESSURISED AIR INLET VALVES DN 15 TO DN 50 INCLUSIVE - FAMILY L, TYPE A AND TYPE B |
04/30126819 DC : DRAFT DEC 2004 | EN 15096 - HOSE UNION ANTI-VACUUM VALVES - DN15 TO DN25 INCLUSIVE FAMILY H, TYPE B AND TYPE D - GENERAL TECHNICAL SPECIFICATION |
PREN 1287 : DRAFT 2015 | SANITARY TAPWARE - LOW PRESSURE THERMOSTATIC MIXING VALVES - GENERAL TECHNICAL SPECIFICATION |
DIN EN 1287:2015-07 (Draft) | SANITARY TAPWARE - LOW PRESSURE THERMOSTATIC MIXING VALVES - GENERAL TECHNICAL SPECIFICATION |
DIN EN 13434:2006-05 | DEVICES TO PREVENT POLLUTION BY BACKFLOW OF POTABLE WATER - MECHANICAL DISCONNECTOR, HYDRAULIC ACTUATED - FAMILY G - TYPE B |
DIN EN 13433:2006-05 | DEVICES TO PREVENT POLLUTION BY BACKFLOW OF POTABLE WATER - MECHANICAL DISCONNECTOR, DIRECT ACTUATED - FAMILY G - TYPE A |
BS EN 15091:2013 | Sanitary tapware. Electronic opening and closing sanitary tapware |
DIN EN 15091:2014-03 | SANITARY TAPWARE - ELECTRONIC OPENING AND CLOSING SANITARY TAPWARE |
BS EN 13433:2007 | Devices to prevent pollution by backflow of potable water. Mechanical disconnector, direct actuated. Family G, type A |
BS EN 14367:2005 | Non controllable backflow preventer with different pressure zones. Family C, type A |
EN 1111:2017 | Sanitary tapware - Thermostatic mixing valves (PN 10) - General technical specification |
EN 13433:2006 | Devices to prevent pollution by backflow of potable water - Mechanical disconnector, direct actuated - Family G, type A |
DIN EN 14367:2005-10 | Non controllable backflow preventer with different pressure zones - Family C, type A |
EN 1287:2017 | Sanitary tapware - Low pressure thermostatic mixing valves - General technical specification |
DIN EN 1287:2017-10 | SANITARY TAPWARE - LOW PRESSURE THERMOSTATIC MIXING VALVES - GENERAL TECHNICAL SPECIFICATION |
DIN EN 816:2017-10 | SANITARY TAPWARE - AUTOMATIC SHUT-OFF VALVES PN 10 |
DIN EN 1111:2017-10 | SANITARY TAPWARE - THERMOSTATIC MIXING VALVES (PN 10) - GENERAL TECHNICAL SPECIFICATION |
15/30328393 DC : 0 | BS EN 816 - SANITARY TAPWARE - AUTOMATIC SHUT-OFF VALVES PN 10 |
DIN EN 1487:2000-06 | BUILDING VALVES - HYDRAULIC SAFETY GROUPS - TESTS AND REQUIREMENTS |
I.S. EN 1111:2017 | SANITARY TAPWARE - THERMOSTATIC MIXING VALVES (PN 10) - GENERAL TECHNICAL SPECIFICATION |
I.S. EN 15091:2013 | SANITARY TAPWARE - ELECTRONIC OPENING AND CLOSING SANITARY TAPWARE |
I.S. EN 13434:2006 | DEVICES TO PREVENT POLLUTION BY BACKFLOW OF POTABLE WATER - MECHANICAL DISCONNECTOR, HYDRAULIC ACTUATED - FAMILY G, TYPE B |
I.S. EN 816:2017 | SANITARY TAPWARE - AUTOMATIC SHUT-OFF VALVES PN 10 |
I.S. EN 1487:2014 | BUILDING VALVES - HYDRAULIC SAFETY GROUPS - TESTS AND REQUIREMENTS |
I.S. EN 13433:2006 | DEVICES TO PREVENT POLLUTION BY BACKFLOW OF POTABLE WATER - MECHANICAL DISCONNECTOR, DIRECT ACTUATED - FAMILY G, TYPE A |
I.S. EN 1287:2017 | SANITARY TAPWARE - LOW PRESSURE THERMOSTATIC MIXING VALVES - GENERAL TECHNICAL SPECIFICATION |
DIN EN 15092:2008-09 | BUILDING VALVES - INLINE HOT WATER SUPPLY TEMPERING VALVES - TESTS AND REQUIREMENTS |
BS EN 15092:2008 | Building valves. Inline hot water supply tempering valves. Tests and requirements |
15/30321799 DC : 0 | BS EN 1287 - SANITARY TAPWARE - LOW PRESSURE THERMOSTATIC MIXING VALVES - GENERAL TECHNICAL SPECIFICATIONS |
15/30321802 DC : 0 | BS EN 1111 - SANITARY TAPWARE - THERMOSTATIC MIXING VALVES (PN 10) - GENERAL TECHNICAL SPECIFICATION |
I.S. EN 15092:2008 | BUILDING VALVES - INLINE HOT WATER SUPPLY TEMPERING VALVES - TESTS AND REQUIREMENTS |
DIN EN 15096:2008-04 | DEVICES TO PREVENT POLLUTION BY BACKFLOW OF POTABLE WATER - HOSE UNION ANTI-VACUUM VALVES - DN 15 TO DN 25 INCLUSIVE FAMILY H, TYPE B AND TYPE D - GENERAL TECHNICAL SPECIFICATION |
UNE-EN 15091:2014 | Sanitary tapware - Electronic opening and closing sanitary tapware |
I.S. EN 15096:2008 | DEVICES TO PREVENT POLLUTION BY BACKFLOW OF POTABLE WATER - HOSE UNION ANTI-VACUUM VALVES - DN 15 TO DN 25 INCLUSIVE FAMILY H, TYPE B AND TYPE D - GENERAL TECHNICAL SPECIFICATION |
DIN EN 1487:2014-09 | BUILDING VALVES - HYDRAULIC SAFETY GROUPS - TESTS AND REQUIREMENTS |
DIN EN 816:2015-11 (Draft) | SANITARY TAPWARE - AUTOMATIC SHUT-OFF VALVES PN 10 |
EN 15096:2008 | Devices to prevent pollution by backflow of potable water - Hose Union anti-vacuum valves - DN 15 to DN 25 inclusive Family H, type B and type D - General technical specification |
UNI EN 1487 : 2014 | BUILDING VALVES - HYDRAULIC SAFETY GROUPS - TESTS AND REQUIREMENTS |
UNI EN 15091 : 2014 | SANITARY TAPWARE - ELECTRONIC OPENING AND CLOSING SANITARY TAPWARE |
BS EN 806-5:2012 | Specifications for installations inside buildings conveying water for human consumption Operation and maintenance |
DIN EN 806-5:2012-04 | Specifications for installations inside buildings conveying water for human consumption - Part 5: Operation and maintenance |
09/30200073 DC : 0 | BS EN 806-5 - SPECIFICATION FOR INSTALLATIONS INSIDE BUILDINGS CONVEYING WATER FOR HUMAN CONSUMPTION - PART 5: OPERATION AND MAINTENANCE |
12/30260007 DC : 0 | BS EN 15091 - SANITARY TAPWARE - ELECTRONIC OPENING AND CLOSING SANITARY TAPWARE |
PREN 15091 : DRAFT 2012 | SANITARY TAPWARE - ELECTRONIC OPENING AND CLOSING SANITARY TAPWARE |
I.S. EN ISO 26722:2015 | WATER TREATMENT EQUIPMENT FOR HAEMODIALYSIS APPLICATIONS AND RELATED THERAPIES (ISO 26722:2014) |
PREN 816 : DRAFT 2015 | SANITARY TAPWARE - AUTOMATIC SHUT-OFF VALVES PN 10 |
EN 12897:2016 | Water supply - Specification for indirectly heated unvented (closed) storage water heaters |
BS EN 1487:2014 | Building valves. Hydraulic safety groups. Tests and requirements |
BS EN 1111:2017 | Sanitary tapware. Thermostatic mixing valves (PN 10). General technical specification |
BS EN 816:2017 | Sanitary tapware. Automatic shut-off valves PN 10 |
BS EN 1287:2017 | Sanitary tapware. Low pressure thermostatic mixing valves. General technical specification |
BS EN 13434:2006 | Devices to prevent pollution by backflow of potable water. Mechanical disconnector, hydraulic actuated. Family G, type B |
BS EN 12897:2016 | Water supply. Specification for indirectly heated unvented (closed) storage water heaters |
DIN EN 14455:2005-08 | Devices to prevent pollution by backflow of potable water - Pressurised air inlet valves DN 15 to DN 50 - Family L, type A and type B |
EN 14455:2005 | Devices to prevent pollution by backflow of potable water - Presssurised air inlet valves DN 15 to DN 50 - Family L, type A and type B |
EN 15092:2008 | Building valves - Inline hot water supply tempering valves - Tests and requirements |
EN ISO 26722:2015 | Water treatment equipment for haemodialysis applications and related therapies (ISO 26722:2014) |
EN 15091:2013 | Sanitary tapware - Electronic opening and closing sanitary tapware |
EN 1487:2014 | Building valves - Hydraulic safety groups - Tests and requirements |
EN 816:2017 | Sanitary tapware - Automatic shut-off valves PN 10 |
EN 14367:2005 | Non controllable backflow preventer with different pressure zones - Family C, type A |
EN 806-5:2012 | Specifications for installations inside buildings conveying water for human consumption - Part 5: Operation and maintenance |
13/30280715 DC : 0 | BS EN 1287 - SANITARY TAPWARE - LOW PRESSURE THERMOSTATIC MIXING VALVES - GENERAL TECHNICAL SPECIFICATIONS |
PREN 1111 : DRAFT 2015 | SANITARY TAPWARE - THERMOSTATIC MIXING VALVES (PN 10) - GENERAL TECHNICAL SPECIFICATION |
13/30280712 DC : 0 | BS EN 1111 - SANITARY TAPWARE - THERMOSTATIC MIXING VALVES (PN 10) - GENERAL TECHNICAL SPECIFICATION |
UNI EN 806-5 : 2012 | SPECIFICATIONS FOR INSTALLATIONS INSIDE BUILDINGS CONVEYING WATER FOR HUMAN CONSUMPTION - PART 5: OPERATION AND MAINTENANCE |
UNI EN 15092 : 2008 | BUILDING VALVES - INLINE HOT WATER SUPPLY TEMPERING VALVES - TESTS AND REQUIREMENTS |
BS EN 15096:2008 | Devices to prevent pollution by backflow of potable water. Hose Union anti-vacuum valves. DN 15 to DN 25 inclusive Family H, type B and type D. General technical specification |
I.S. EN 806-5:2012 | SPECIFICATIONS FOR INSTALLATIONS INSIDE BUILDINGS CONVEYING WATER FOR HUMAN CONSUMPTION - PART 5: OPERATION AND MAINTENANCE |
UNE-EN 806-5:2013 | Specifications for installations inside buildings conveying water for human consumption - Part 5: Operation and maintenance |
DIN EN 1111:2015-07 (Draft) | SANITARY TAPWARE - THERMOSTATIC MIXING VALVES (PN 10) - GENERAL TECHNICAL SPECIFICATION |
I.S. EN 61770:2009 | ELECTRIC APPLIANCES CONNECTED TO THE WATER MAINS - AVOIDANCE OF BACKSIPHONAGE AND FAILURE OF HOSE-SETS |
I.S. EN 12897:2016 | WATER SUPPLY - SPECIFICATION FOR INDIRECTLY HEATED UNVENTED (CLOSED) STORAGE WATER HEATERS |
UNE-EN 12897:2017 | Water supply - Specification for indirectly heated unvented (closed) storage water heaters |
BS EN 14455:2005 | Devices to prevent pollution by backflow of potable water. Pressurised air inlet valves DN 15 to DN 50. Family L, type A and type B |
EN 13434:2006 | Devices to prevent pollution by backflow of potable water - Mechanical disconnector, hydraulic actuated - Family G, type B |
EN 61770:2009/A11:2018 | ELECTRIC APPLIANCES CONNECTED TO THE WATER MAINS - AVOIDANCE OF BACKSIPHONAGE AND FAILURE OF HOSE-SETS |
ISO 3822-1:1999 | Acoustics Laboratory tests on noise emission from appliances and equipment used in water supply installations Part 1: Method of measurement |
ISO 5167-3:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 3: Nozzles and Venturi nozzles |
EN 1254-3:1998 | Copper and copper alloys - Plumbing fittings - Part 3: Fittings with compression ends for use with plastics pipes |
EN 1254-1:1998 | Copper and copper alloys - Plumbing fittings - Part 1: Fittings with ends for capillary soldering or capillary brazing to copper tubes |
EN 1254-2:1998 | Copper and copper alloys - Plumbing fittings - Part 2: Fittings with compression ends for use with copper tubes |
EN 558-1 : 1995 | INDUSTRIAL VALVES - FACE-TO-FACE AND CENTRE-TO-FACE DIMENSIONS OF METAL VALVES FOR USE IN FLANGED PIPE SYSTEMS - PN-DESIGNATED VALVES |
EN 1717:2000 | Protection against pollution of potable water in water installations and general requirements of devices to prevent pollution by backflow |
EN ISO 5167-3:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 3: Nozzles and Venturi nozzles (ISO 5167-3:2003) |
ISO 6509:1981 | Corrosion of metals and alloys Determination of dezincification resistance of brass |
ISO 9227:2017 | Corrosion tests in artificial atmospheres — Salt spray tests |
ISO 3822-3:1997 | Acoustics Laboratory tests on noise emission from appliances and equipment used in water supply installations Part 3: Mounting and operating conditions for in-line valves and appliances |
EN ISO 6509:1995 | Corrosion of metals and alloys - Determination of dezincification resistance of brass (ISO 6509:1981) |
EN 1092-2:1997 | Flanges and their joints - Circular flanges for pipes, valves, fittings and accessories, PN designated - Part 2: Cast iron flanges |
EN 1267:2012 | Industrial valves - Test of flow resistance using water as test fluid |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.