C22.2 NO. 31-18
Current
The latest, up-to-date edition.
Switchgear assemblies
Hardcopy , PDF
English
01-01-2018
Preface
1 Scope
2 Reference publications
3 Definitions
4 Construction
5 Marking
6 Tests
7 Low-voltage switchgear assemblies
8 High-voltage switchgear assemblies
Annex A (Normative) - French translations of cautions, warnings,
and safety instructions
Annex B (Informative) - Method of measurement of spacings
when insulating barriers are used
Annex C (Normative) - Impulse testing
Annex D (Informative) - Guide to the measurement of corona in
switchgear assemblies
Annex E (Informative) - Method for conducting temperature tests
Annex F (Normative) - Pressurized gas insulated switchgear
Annex G (Informative) - Tightness of pressurized gas insulated
switchgear
Annex H (Informative) - Illustration of defined terms 'unit'
and 'compartment'
Pertains to deadfront indoor enclosed and outdoor enclosed assemblies of switchgear devices such as: a) switches; b) interrupting devices; c) air circuit breakers; d) power circuit breakers; and e) control, metering, protective, and regulating equipment with associated interconnections and supporting structures.
DocumentType |
Standard
|
ISBN |
978-1-4883-1268-7
|
Pages |
92
|
PublisherName |
Canadian Standards Association
|
Status |
Current
|
Supersedes |
Preface This is the eleventh edition of CSA C22.2 No. 31, Switchgear assemblies . It supersedes previous editions, published in 2014, 2010, 2004, 1989, 1983, 1977, 1972, 1965, 1958, and 1939. It is one of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. For general information on the Standards of the Canadian Electrical Code, Part II, see the Preface of CAN/CSA-C22.2 No. 0. The applicable requirements of CSA TIL D-06 are incorporated in this Standard. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard applies to deadfront indoor enclosed and outdoor enclosed assemblies of switchgear devices such as a) switches; b) interrupting devices; c) air circuit breakers; d) power circuit breakers; and e) control, metering, protective, and regulating equipment with associated interconnections and supporting structures. 1.2 This Standard covers equipment with a nominal voltage of 46 kV or less that is intended to be used a) in accordance with the Canadian Electrical Code, Part I; b) in non-hazardous locations; c) for controlling and protecting the power from generators or other sources; and d) for supplying electrical energy to power and lighting circuits. 1.3 This Standard does not apply to panelboards, industrial control equipment, switchboards for communication circuits, or low-voltage assemblies consisting of separately supported enclosed switches, enclosed circuit breakers, and possibly service meters, with interconnection between them enclosed in raceways. Note: Manufacturers and installers of switchgear assemblies approved under this Standard should take due note of the Canadian Electrical Code, Part I, with respect to the location of switchgear devices in areas where certain components might not be acceptable. 1.4 Clauses 2 to 6 apply to all switchgear assemblies and are supplemented and amended by a) Clause 7 for low-voltage switchgear assemblies; and b) Clause 8 for high-voltage switchgear assemblies. 1.5 In this Standard, \"shall\" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; \"should\" is used to express a recommendation or that which is advised but not required; and \"may\" is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.
IEC 60480:2004 | Guidelines for the checking and treatment of sulfur hexafluoride (SF<sub>6</sub>) taken from electrical equipment and specification for its re-use |
IEC 62271-100:2008+AMD1:2012+AMD2:2017 CSV | High-voltage switchgear and controlgear - Part 100: Alternating-current circuit-breakers |
IEEE C37.20.1-2015 | IEEE Standard for Metal-Enclosed Low-Voltage (1000 Vac and below, 3200 Vdc and below) Power Circuit Breaker Switchgear |
CSA C22 NO. 4 : 2016 | ENCLOSED AND DEAD-FRONT SWITCHES |
IEC 62271-200:2011 | High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
CSA C22.2 No. 5 : 2013 | MOLDED-CASE CIRCUIT BREAKERS, MOLDED-CASE SWITCHES AND CIRCUIT-BREAKER ENCLOSURES |
ANSI C37.51 : 1989 | SWITCHGEAR - METAL-ENCLOSED LOW-VOLTAGE AC POWER - CIRCUIT BREAKER SWITCHGEAR ASSEMBLIES - CONFORMANCE TEST PROCEDURES |
IEEE C37.20.2-2015 | IEEE Standard for Metal-Clad Switchgear |
IEC 60376:2005 | Specification of technical grade sulfur hexafluoride (SF<sub>6</sub>) for use in electrical equipment |
CSA C22.2 No. 178.1 : 2014 | TRANSFER SWITCH EQUIPMENT |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
IEEE 4-2013 | IEEE Standard for High-Voltage Testing Techniques |
IEEE C37.20.3-2013 REDLINE | IEEE Standard for Metal-Enclosed Interrupter Switchgear (1 kV-38 kV) |
IEEE C37.13-2015 | IEEE Standard for Low-Voltage AC Power Circuit Breakers Used in Enclosures |
IEC 60068-2-17:1994 | Basic environmental testing procedures - Part 2-17: Tests - Test Q: Sealing |
IEC TR 60943:1998+AMD1:2008 CSV | Guidance concerning the permissible temperature rise for parts of electrical equipment, in particular for terminals |
ASTM D 2472 : 2015 : REDLINE | Standard Specification for Sulfur Hexafluoride |
ASTM G 155 : 2013 : REDLINE | Standard Practice for Operating Xenon Arc Light Apparatus for Exposure of Non-Metallic Materials |
IEC 62271-1:2017 | High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear |
IEEE C37.16-2009 | IEEE Standard for Preferred Ratings,Related Requirements, and Application Recommendations for Low-Voltage AC (635 V and below)and DC (3200 V and below) Power Circuit Breakers |
ASTM D 1868 : 2013 : REDLINE | Standard Test Method for Detection and Measurement of Partial Discharge (Corona) Pulses in Evaluation of Insulation Systems |
IEC 61439-1:2011 | Low-voltage switchgear and controlgear assemblies - Part 1: General rules |
IEEE C37.12-2008 REDLINE | IEEE Guide for Specifications of High-Voltage Circuit Breakers (over 1000 Volts) |
IEC 60947-2:2016 | Low-voltage switchgear and controlgear - Part 2: Circuit-breakers |
IEEE C57.12.28-2014 | IEEE Standard for Pad-Mounted Equipment--Enclosure Integrity |
CSA C22.2 No. 94.2 : 2015 | ENCLOSURES FOR ELECTRICAL EQUIPMENT, ENVIRONMENTAL CONSIDERATIONS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.