BS 5410-2:2013
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Code of practice for oil firing Installations over 45 kW output capacity for space heating, hot water and steam supply services
Hardcopy , PDF
30-04-2018
English
31-03-2013
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Work undertaken in connection with oil fired
installations
5 Liquid fuels
6 Application of oil burners
7 Selection of burners
8 Oil tanks and equipment
9 Oil handling systems from storage tank to burner
10 Design and construction of accommodation
for oil fired installations
11 Chimney and flue systems
12 Electrical equipment
13 Instrumentation
14 Commissioning, performance tests and handover
15 Maintenance
16 Safety provisions
17 Biofuels
Bibliography
Provides recommendations and guidance on the design, installation, commissioning and maintenance of oil burning installations for heating, hot water and steam supply services having a total rated output of over 45 kW and/or an oil storage capacity above 3500 L.
Committee |
RHE/13
|
DevelopmentNote |
Supersedes BS 5410-2(1978) & 12/30170835 DC. (04/2013)
|
DocumentType |
Standard
|
Pages |
98
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This part of BS 5410 gives recommendations and guidance on the design, installation, commissioning and maintenance of oil burning installations for heating, hot water and steam supply services having a total rated output of over 45 kW and/or an oil storage capacity above 3 500 L.
This part of BS 5410 is applicable to installations burning liquid fuel conforming to BS 2869:2010+A1, including biofuels, for example those containing fatty acid methyl esters (FAME) conforming to BS EN 14214, and blends thereof.
The standard covers the provision of new installations and also gives guidance on the modernizing of existing installations. The standard also gives recommendations and guidance on the selection and installation of oil tanks associated with these installations.
This part of BS 5410 is applicable to the oil burning equipment forming part of a multi-fuel installation in which oil is not burnt simultaneously with any other fuel. It is not applicable to oil fired systems for marine installations. The standard also gives recommendations on thermal fluid heaters and on portable plants, for example those used for emergency or temporary heat supply.
The standard is intended for use by designers, specifiers, installers and building owners.
BS 9999:2017 | Fire safety in the design, management and use of buildings. Code of practice |
BS 5410-1:2014 | Code of practice for oil firing Installations up to 45 kW output capacity for space heating and hot water supply purposes |
BS 5925:1991 | Code of practice for ventilation principles and designing for natural ventilation |
BS 2869:2017 | Fuel oils for agricultural, domestic and industrial engines and boilers Specification |
BS 799-3:1981 | Oil burning equipment Automatic and semi-automatic atomizing burners up to 36 litres per hour |
BS 9991:2015 | Fire safety in the design, management and use of residential buildings. Code of practice |
BS 5410-3:2016 | Code of practice for oil firing Installations for furnaces, kilns, ovens, oil-fuelled generators and other industrial purposes |
BS 845-1:1987 | Methods for assessing thermal performance of boilers for steam, hot water and high temperature heat transfer fluids Concise procedure |
BS EN 13341 : 2005 | STATIC THERMOPLASTIC TANKS FOR ABOVE GROUND STORAGE OF DOMESTIC HEATING OILS, KEROSENE AND DIESEL FUELS - BLOW MOULDED AND ROTATIONALLY MOULDED POLYETHYLENE TANKS AND ROTATIONALLY MOULDED TANKS MADE OF ANIONICALLY POLYMERIZED POLYAMIDE 6 - REQUIREMENTS AND TEST METHODS |
BS 845-2:1987 | Methods for assessing thermal performance of boilers for steam, hot water and high temperature heat transfer fluids. Comprehensive procedure |
DD CLC/TS 62395-2:2010 | Electrical resistance trace heating systems for industrial and commercial applications Application guide for system design, installation and maintenance |
BS EN 62271-106:2011 | High-voltage switchgear and controlgear Alternating current contactors, contactor-based controllers and motor-starters |
BS EN 13959:2004 | Anti-pollution check valves. DN 6 to DN 250 inclusive Family E, type A, B, C, and D |
BS 1710:1984 | Specification for identification of pipelines and services |
BS EN 13842:2004 | Oil fired forced convection air heaters. Stationary and transportable for space heating |
BS EN ISO 23553-1:2014 | Safety and control devices for oil burners and oil-burning appliances. Particular requirements Automatic and semi-automatic valves |
BS EN 1857 : 2003 | CHIMNEYS - COMPONENTS - CONCRETE FLUE LINERS |
BS EN 13077:2008 | Devices to prevent pollution by backflow of potable water. Air gap with non-circular overflow (unrestricted). Family A. Type B |
BS 6700(2006) : 2006 | DESIGN, INSTALLATION, TESTING AND MAINTENANCE OF SERVICES SUPPLYING WATER FOR DOMESTIC USE WITHIN BUILDINGS AND THEIR CURTILAGES - SPECIFICATION |
BS 6880-2:1988 | Code of practice for low temperature hot water heating systems of output greater than 45 kW Selection of equipment |
BS EN 303-2:2017 | Heating boilers Heating boilers with forced draught burners. Special requirements for boilers with atomizing oil burners |
BS EN 303-1:2017 | Heating boilers Heating boilers with forced draught burners. Terminology, general requirements, testing and marking |
BS EN 60079-15:2010 | Explosive atmospheres Equipment protection by type of protection \'n\' |
BS EN 12285-1:2003 | Workshop fabricated steel tanks Horizontal cylindrical single skin and double skin tanks for the underground storage of flammable and non-flammable water polluting liquids |
BS 1212-2:1990 | Float operated valves Specification for diaphragm type float operated valves (copper alloy body) (excluding floats) |
SAE J513_199901 | REFRIGERATION TUBE FITTINGS - GENERAL SPECIFICATIONS |
BS EN 303-4:1999 | Heating boilers. Heating boilers with forced draught burners Heating boilers with forced draught burners. Special requirements for boilers with forced draught oil burners with outputs up to 70 kW and a maximum operating pressure of 3 bar. Terminology, special requirements, testing and marking |
BS EN 13069:2005 | Chimneys. Clay/ceramic outer walls for system chimneys. Requirements and test methods |
BS 7671(2008) : 2008 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
BS EN 12285-2:2005 | Workshop fabricated steel tanks Horizontal cylindrical single skin and double skin tanks for the aboveground storage of flammable and non-flammable water polluting liquids |
BS EN 12514-2:2000 | Installations for oil supply systems for oil burners Safety requirements and tests. Parts, valves, pipes, filters, oil de-aerators, meters |
BS EN 14622:2005 | Devices to prevent pollution by backflow of potable water. Air gap with circular overflow (restricted). Family A, type F |
BS EN 60079-14:2014 | Explosive atmospheres Electrical installations design, selection and erection |
BS EN 13076:2003 | Devices to prevent pollution by backflow of potable water. Unrestricted air gap. Family A. Type A |
BS EN 62395-1:2013 | Electrical resistance trace heating systems for industrial and commercial applications General and testing requirements |
BS EN 60079-30-1:2017 | Explosive atmospheres Electrical resistance trace heating. General and testing requirements |
BS EN 267 : 2009 | AUTOMATIC FORCED DRAUGHT BURNERS FOR LIQUID FUELS |
BS 476-21:1987 | Fire tests on building materials and structures Methods for determination of the fire resistance of loadbearing elements of construction |
BS EN 1254-2:1998 | Copper and copper alloys. Plumbing fittings Fittings with compression ends for use with copper tubes |
BS 7860:1996 | Specification for carbon monoxide detectors (electrical) for domestic use |
BS EN 13831:2007 | Closed expansion vessels with built-in diaphragm for installation in water |
BS EN 1457:1999 | Chimneys. Clay/ceramic flue liners. Requirements and test methods |
BS 5410-1:1997 | Code of practice for oil firing Installations up to 45 kW output capacity for space heating and hot water supply purposes |
BS EN 50291:2001 | Electrical apparatus for the detection of carbon monoxide in domestic premises. Test methods and performance requirements |
BS EN 1856-1:2009 | Chimneys. Requirements for metal chimneys System chimney products |
BS EN 1567 : 2000 | BUILDING VALVES - WATER PRESSURE REDUCING VALVES AND COMBINATION WATER REDUCING VALVES - REQUIREMENTS AND TESTS |
BS EN 60947-4-1 : 2010 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 4-1: CONTACTORS AND MOTOR-STARTERS - ELECTROMECHANICAL CONTACTORS AND MOTOR-STARTERS |
BS EN 1859 : 2009 | CHIMNEYS - METAL CHIMNEYS - TEST METHODS |
BS EN 1856-2:2009 | Chimneys. Requirements for metal chimneys Metal flue liners and connecting flue pipes |
BS EN 13216-1:2004 | Chimneys. Test methods for system chimneys General test methods |
BS EN 12446:2011 | Chimneys. Components. Concrete outer wall elements |
BS EN 60079-30-2:2007 | Explosive atmospheres Electrical resistance trace heating. Application guide for design, installation and maintenance |
BS 5422:2009 | Method for specifying thermal insulating materials for pipes, tanks, vessels, ductwork and equipment operating within the temperature range -40°C to +700°C |
BS EN ISO 4126-1 : 2013 | SAFETY DEVICES FOR PROTECTION AGAINST EXCESSIVE PRESSURE - PART 1: SAFETY VALVES (ISO 4126-1:2013) |
BS 476-22:1987 | Fire tests on building materials and structures Method for determination of the fire resistance of non-loadbearing elements of construction |
BS EN 14214:2012 | LIQUID PETROLEUM PRODUCTS - FATTY ACID METHYL ESTERS (FAME) FOR USE IN DIESEL ENGINES AND HEATING APPLICATIONS - REQUIREMENTS AND TEST METHODS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.