Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

ASTM E 2823 : 2011

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Test Method for Analysis of Nickel Alloys by Inductively Coupled Plasma Mass Spectrometry (Performance-Based Method)

Available format(s)

Hardcopy , PDF

Superseded date

11-11-2014

Superseded by

ASTM E 2823 : 2017

Language(s)

English

Published date

01-05-2011

$122.77
Including GST where applicable

Committee
E 01
DocumentType
Test Method
Pages
8
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy

1.1 This test method describes the inductively coupled plasma mass spectrometric analysis of nickel, as specified by Committee B02, and having chemical compositions within the following limits:

ElementApplication Range (Wt. %)
Aluminum0. 016.00
Boron0. 010.10
Carbon0. 010.15
Chromium0. 0133.00
Copper0.0135.00
Cobalt0. 0120.00
Iron0.0550.00
Magnesium0. 010.020
Molybdenum0. 0130.0
Niobium0. 016.0
Nickel25.00100.0
Phosphorous0.0010.025
Silicon0.011.50
Sulfur0.00010.01
Titanium0.00016.0
Tungsten0.015.0
Vanadium0.00051.0

1.2 The following elements may be determined using this method.

ElementQuantification Range (μg/g)
Antimony0.550
Bismuth0.111
Gallium2.954
Lead0.421
Silver135
Tin2.297
Thallium0.53.0

1.3 This method has only been interlaboratory tested for the elements and ranges specified. It may be possible to extend this method to other elements or different composition ranges provided that method validation that includes evaluation of method sensitivity, precision, and bias as described in this document is performed. Additionally, the validation study must evaluate the acceptability of sample preparation methodology using reference materials and/or spike recoveries. The user is cautioned to carefully evaluate the validation data as to the intended purpose of the analytical results.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific safety hazard statements are given in Section 9.

ASTM E 1473 : 2016 Standard Test Methods for Chemical Analysis of Nickel, Cobalt and High-Temperature Alloys

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.