07/30145258 DC : 0
Superseded
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
BS ISO 20072 - AEROSOL DRUG DELIVERY DEVICES DESIGN VERIFICATION - REQUIREMENTS AND TEST METHODS
Available format(s)
Hardcopy , PDF
Language(s)
English
Publisher
Superseded date
31-12-2010
Superseded by
Including GST where applicable
| Committee |
CH/84
|
| DocumentType |
Draft
|
| Pages |
42
|
| PublisherName |
British Standards Institution
|
| Status |
Superseded
|
| SupersededBy |
| IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
| IEC 60601-1:2005+AMD1:2012 CSV | Medical electrical equipment - Part 1: General requirements for basic safety and essential performance |
| ISO 14253-1:2017 | Geometrical product specifications (GPS) — Inspection by measurement of workpieces and measuring equipment — Part 1: Decision rules for verifying conformity or nonconformity with specifications |
| ISO 13485:2016 | Medical devices — Quality management systems — Requirements for regulatory purposes |
| IEC 60721-3-7:1995+AMD1:1996 CSV | Classification of environmental conditions - Part 3-7: Classification of groups of environmental parameters and their severities - Portable and non-stationary use |
| IEC 60601-1-8:2006+AMD1:2012 CSV | Medical electrical equipment - Part 1-8: General requirements forbasic safety and essential performance - Collateral Standard: General requirements, tests and guidance for alarm systems inmedical electrical equipment and medical electrical systems |
| IEC 60068-2-64:2008 | Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance |
| ISO 11135-1:2007 | Sterilization of health care products — Ethylene oxide — Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices |
| IEC 60601-1-2:2014 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
| ISO 16269-6:2014 | Statistical interpretation of data — Part 6: Determination of statistical tolerance intervals |
| ISO 15378:2017 | Primary packaging materials for medicinal products — Particular requirements for the application of ISO 9001:2015, with reference to good manufacturing practice (GMP) |
| IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
| IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
| ISO 9001:2015 | Quality management systems — Requirements |
| ISO 14155:2011 | Clinical investigation of medical devices for human subjects — Good clinical practice |
| ISO 14971:2007 | Medical devices — Application of risk management to medical devices |
| ISO 11137:1995 | Sterilization of health care products — Requirements for validation and routine control — Radiation sterilization |
| IEC 60601-1-4:1996+AMD1:1999 CSV | Medical electrical equipment - Part 1-4: General requirements for safety - Collateral Standard: Programmable electrical medical systems |
| ISO 27427:2013 | Anaesthetic and respiratory equipment — Nebulizing systems and components |
| ISO 17665-1:2006 | Sterilization of health care products — Moist heat — Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices |
| IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |